Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1680743.1
Update Date:2016-06-12
Keywords:

Solution Type  Problem Resolution Sure

Solution  1680743.1 :   The Major Event Log of the Sun Storage 2500 and 6000 Arrays Reports Component Locations as "UNDEFINED"  


Related Items
  • Sun Storage 6580 Array
  •  
  • Sun Storage 6180 Array
  •  
  • Sun Storage 6780 Array
  •  
  • Sun Storage 2510 Array
  •  
  • Sun Storage 2540 Array
  •  
  • Sun Storage 6140 Array
  •  
  • Sun Storage 2530 Array
  •  
  • Sun Storage Flexline 380 Array
  •  
  • Sun Storage 6540 Array
  •  
  • Sun Storage 6130 Array
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>Arrays>SN-DK: 6130
  •  




In this Document
Symptoms
Cause
Solution
References


Applies to:

Sun Storage 6780 Array - Version Not Applicable and later
Sun Storage 2530 Array - Version Not Applicable and later
Sun Storage 2510 Array - Version Not Applicable and later
Sun Storage 6140 Array - Version Not Applicable and later
Sun Storage 2540 Array - Version Not Applicable and later
Information in this document applies to any platform.

Symptoms

The Major Event Log (MEL) is a file collected when generating a SupportData with Common Array Manager (CAM).  Instead of reporting logical locations in the array, they are all showing up as  "UNDEFINED". In this example, the log file is not reporting the location of a disk failure. (The log file has been parsed for simplicity.)

Wed Oct 14 13:45:06 MEST 2009  511   Drive spun down - UNDEFINED
Wed Oct 14 13:45:06 MEST 2009  512   Drive failure detected - UNDEFINED     Critical
Wed Oct 14 13:45:06 MEST 2009  513   Drive marked failed - UNDEFINED
Wed Oct 14 13:45:06 MEST 2009  514   Piece taken out of service - UNDEFINED
Wed Oct 14 13:45:06 MEST 2009  515   Piece failed - UNDEFINED
Wed Oct 14 13:45:06 MEST 2009  516   Piece taken out of service - UNDEFINED
Wed Oct 14 13:45:06 MEST 2009  517   Piece failed - UNDEFINED
Wed Oct 14 13:45:06 MEST 2009  518   Piece taken out of service - UNDEFINED
Wed Oct 14 13:45:06 MEST 2009  519   Piece failed - UNDEFINED
Wed Oct 14 13:45:31 MEST 2009  520   Fail drive - UNDEFINED
Wed Oct 14 13:45:31 MEST 2009  521   Drive manually failed - UNDEFINED
  

Cause

 There is a bug in firmware which has been fixed in the following releases.

  • 6000 series arrays running the 07.xx.xx firmware need to be upgraded to 07.60.36.10(bundled with CAM 6.6.0.12) or later. Review the firmware matrix for your respective array type
  • 25xx series arrays running the 07.xx.xx firmware need to be upgraded to 07.35.55.10(bundled with CAM 6.6.0.12) or later.
  • Arrays running the 06.xx.xx Series firmware need to be upgraded to CAM 6.6 or later.
  • See <Document 1296274.1> How to Download Common Array Manager (CAM) Software and Patches, for assistance with CAM (and subsequent firmware) upgrades.

Solution

Until such upgrades can be scheduled, use the service command to collect the major event log. The log file will correctly report array locations. For example...

Find the service command in:
Solaris: /opt/SUNWSefms/bin
Windows: c:\Program Files\Sun\Common Array Manager\Component\fms\bin
Linux: /opt/sun/cam/private/fms/bin
 
# /opt/SUNWsefms/bin/service -d <arrayname> -c save -t mel -p <data location> -o majorEventLog.txt
  • <arrayname> = The name of the storage array. For example 6140-prod
  • <data location> = the directory where you will save the file. For example /var/tmp
Thu May 23 05:17:57 EAT 2014 Fail drive, 0/0/0, Drive, Tray.02.Drive.07, Controller in slot B
Thu May 23 05:23:45 EAT 2014 Mark drive removed, 0/0/0, Drive, Tray.02.Drive.07, Controller in slot A
Thu May 23 05:23:45 EAT 2014 Hot swap monitor detected drive removal, 0/0/0, Drive, Tray.02.Drive.07, Controller in slot B
Thu May 23 05:18:05 EAT 2014 Piece replaced, 0/0/0, Drive, Tray.02.Drive.07, Controller in slot B
Thu May 23 05:18:05 EAT 2014 Reconstruction started, 0/0/0, Volume, blade07-blackberry-vol, Controller in slot B




References

<BUG:15592976> - SUNBT6886547 EVENT ENTIRES IN MAJOREVENTLOG.TXT (PART OF SUPPORTDATA) SHOW A COM
<BUG:15610063> - SUNBT6909863 MEL FILLED WITH COMPONENT LOCATION: UNDEFINED

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.