![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1680743.1 : The Major Event Log of the Sun Storage 2500 and 6000 Arrays Reports Component Locations as "UNDEFINED"
In this Document
Applies to:Sun Storage 6780 Array - Version Not Applicable and laterSun Storage 2530 Array - Version Not Applicable and later Sun Storage 2510 Array - Version Not Applicable and later Sun Storage 6140 Array - Version Not Applicable and later Sun Storage 2540 Array - Version Not Applicable and later Information in this document applies to any platform. SymptomsThe Major Event Log (MEL) is a file collected when generating a SupportData with Common Array Manager (CAM). Instead of reporting logical locations in the array, they are all showing up as "UNDEFINED". In this example, the log file is not reporting the location of a disk failure. (The log file has been parsed for simplicity.) Wed Oct 14 13:45:06 MEST 2009 511 Drive spun down - UNDEFINED
Wed Oct 14 13:45:06 MEST 2009 512 Drive failure detected - UNDEFINED Critical Wed Oct 14 13:45:06 MEST 2009 513 Drive marked failed - UNDEFINED Wed Oct 14 13:45:06 MEST 2009 514 Piece taken out of service - UNDEFINED Wed Oct 14 13:45:06 MEST 2009 515 Piece failed - UNDEFINED Wed Oct 14 13:45:06 MEST 2009 516 Piece taken out of service - UNDEFINED Wed Oct 14 13:45:06 MEST 2009 517 Piece failed - UNDEFINED Wed Oct 14 13:45:06 MEST 2009 518 Piece taken out of service - UNDEFINED Wed Oct 14 13:45:06 MEST 2009 519 Piece failed - UNDEFINED Wed Oct 14 13:45:31 MEST 2009 520 Fail drive - UNDEFINED Wed Oct 14 13:45:31 MEST 2009 521 Drive manually failed - UNDEFINED
CauseThere is a bug in firmware which has been fixed in the following releases.
SolutionUntil such upgrades can be scheduled, use the service command to collect the major event log. The log file will correctly report array locations. For example... Find the service command in:
Solaris: /opt/SUNWSefms/bin Windows: c:\Program Files\Sun\Common Array Manager\Component\fms\bin Linux: /opt/sun/cam/private/fms/bin # /opt/SUNWsefms/bin/service -d <arrayname> -c save -t mel -p <data location> -o majorEventLog.txt
Thu May 23 05:17:57 EAT 2014 Fail drive, 0/0/0, Drive, Tray.02.Drive.07, Controller in slot B
Thu May 23 05:23:45 EAT 2014 Mark drive removed, 0/0/0, Drive, Tray.02.Drive.07, Controller in slot A Thu May 23 05:23:45 EAT 2014 Hot swap monitor detected drive removal, 0/0/0, Drive, Tray.02.Drive.07, Controller in slot B Thu May 23 05:18:05 EAT 2014 Piece replaced, 0/0/0, Drive, Tray.02.Drive.07, Controller in slot B Thu May 23 05:18:05 EAT 2014 Reconstruction started, 0/0/0, Volume, blade07-blackberry-vol, Controller in slot B References<BUG:15592976> - SUNBT6886547 EVENT ENTIRES IN MAJOREVENTLOG.TXT (PART OF SUPPORTDATA) SHOW A COM<BUG:15610063> - SUNBT6909863 MEL FILLED WITH COMPONENT LOCATION: UNDEFINED Attachments This solution has no attachment |
||||||||||||||||||
|