![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1679796.1 : ORA-27626: Exadata error: 219 (Capability not supported by Cell) in the asm alert log while rolling upgrading cell servers
Created from <SR 3-8959709471> Applies to:Exadata Database Machine X2-2 Hardware - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. SymptomsWhile performing a rolling upgrade on cell nodes, you may see content similar to this in the ASM alert log: Errors in file /u01/app/grid/product/11.2.0.4/grid_infra_1/rdbms/log/+asm1_rbal_115692.trc:
ORA-27603: Cell storage I/O error, I/O failed on disk o/192.168.10.100/DBFS_DG_CD_08_exa01cel01 at offset 0 for data length 4096 ORA-27626: Exadata error: 202 (Inappropriate Griddisk state) WARNING: Read Failed. group:1 disk:31 AU:0 offset:0 size:4096 There doesn't seem to be a problem with the actual transactions. CauseThis has been presented to development under unpublished Bug 18781327 GRIDDISK SECURTdmITY ERROR MESSAGE DURING PATCHING, which is closed as Not a Bug: It can be confirmed from the code or trace that cellsrv marks griddisk as inactive after offline query succeeded. There is no database impact and this is expected behavior. SolutionNo action is needed. References<BUG:18781327> - GRIDDISK SECURTITY ERROR MESSAGE DURING PATCHINGAttachments This solution has no attachment |
||||||||||||
|