![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1679004.1 : ERROR: /pci@7c0/pci@0/pci@1/pci@0/usb@6: Last Trap: Level 15 Interrupt
Fatal Error after OS is reloaded In this Document
Created from <SR 3-8979913552> Applies to:Sun SPARC Enterprise T2000 Server - Version All Versions and laterOracle Solaris on SPARC (64-bit) SymptomsAfter the OS is reloaded on a previously used T2000 server the hardware shows errors when it's booted through init 6 or reset commands: Example: # init 6
# svc.startd: The system is coming down. Please wait. svc.startd: 71 system services are now being stopped. May 9 15:47:06 testbox20 syslogd: going down on signal 15 svc.startd: The system is down. syncing file systems... done rebooting... Resetting... ERROR: /pci@7c0/pci@0/pci@1/pci@0/usb@6: Last Trap: Level 15 Interrupt {0} ok boot FATAL: /pci@7c0/pci@0/pci@1/pci@0/usb@6: OpenBoot initialization sequence prema. FATAL: system is not bootable, boot command is disabled {0} ok
CauseApparently due to conflicting pre existing ldom configuration. SolutionReset the SC bootmode config to factory-defaults and then reload the OS. Command Usage: sc> bootmode config="factory-default" References<NOTE:1005907.1> - SPARC Platforms: Matrix of Recognized Device Paths<NOTE:1518881.1> - Recognizing and Troubleshooting an Incomplete System Service Processor (SP) Firmware Upgrade on T2000 Series <NOTE:1153444.1> - Oracle Services Tools Bundle (STB) - RDA/Explorer, SNEEP, ACT <NOTE:1006990.1> - Oracle Explorer Data Collector Implementation Best Practice <NOTE:1312847.1> - Oracle Explorer Data Collector Resource Center <NOTE:1004230.1> - Troubleshooting Firmware Upgrade Issues on a T1000/T2000 Attachments This solution has no attachment |
||||||||||||||||||
|