Solution Type  Problem Resolution Sure

Solution  1679004.1 :   ERROR: /pci@7c0/pci@0/pci@1/pci@0/usb@6: Last Trap: Level 15 Interrupt  


Related Items
  • Sun SPARC Enterprise T2000 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>CMT>SN-SPARC: Tx000
  •  


Fatal Error after OS is reloaded

In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-8979913552>

Applies to:

Sun SPARC Enterprise T2000 Server - Version All Versions and later
Oracle Solaris on SPARC (64-bit)

Symptoms

After the OS is reloaded on a previously used T2000 server the hardware shows errors when it's booted through init 6 or reset commands:

Example:

# init 6
# svc.startd: The system is coming down. Please wait.
svc.startd: 71 system services are now being stopped.
May 9 15:47:06 testbox20 syslogd: going down on signal 15
svc.startd: The system is down.
syncing file systems... done
rebooting...
Resetting...

ERROR: /pci@7c0/pci@0/pci@1/pci@0/usb@6: Last Trap: Level 15 Interrupt
{0} ok boot
FATAL: /pci@7c0/pci@0/pci@1/pci@0/usb@6: OpenBoot initialization sequence prema.

FATAL: system is not bootable, boot command is disabled
{0} ok


When powered off/on via ALOM or power button the error is not reported.

Cause

Apparently due to conflicting pre existing ldom configuration.
 

Solution

Reset the SC bootmode config to factory-defaults and then reload the OS.

Command Usage:

sc> bootmode config="factory-default"
sc> poweroff

   Wait for system to power off.

sc> poweron -c
OR
sc> poweron
 

References

<NOTE:1005907.1> - SPARC Platforms: Matrix of Recognized Device Paths
<NOTE:1518881.1> - Recognizing and Troubleshooting an Incomplete System Service Processor (SP) Firmware Upgrade on T2000 Series
<NOTE:1153444.1> - Oracle Services Tools Bundle (STB) - RDA/Explorer, SNEEP, ACT
<NOTE:1006990.1> - Oracle Explorer Data Collector Implementation Best Practice
<NOTE:1312847.1> - Oracle Explorer Data Collector Resource Center
<NOTE:1004230.1> - Troubleshooting Firmware Upgrade Issues on a T1000/T2000

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback