Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1677413.1
Update Date:2018-05-08
Keywords:

Solution Type  Problem Resolution Sure

Solution  1677413.1 :   Fujitsu M10-4S Error: Using PPAR Dynamic Reconfiguration ( DR ) on Multi Building Block Configuration May Cause Memory Corruption, OS Panic or PPAR Reset.  


Related Items
  • Fujitsu M10-4S
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Enterprise>SN-SPARC: Fujitsu M10
  •  




Applies to:

Fujitsu M10-4S - Version All Versions and later
Information in this document applies to any platform.

Symptoms

Releasing a system board by using Physical Partition Dynamic Reconfiguration (PPAR DR), may cause memory corruption, OS panic or Physical Partition reset (Hypervisor Abort) in the following conditions.

  1. SPARC M10-4S and two or more Building Blocks(BB) System (2BB or more), and
  2. A physical partition has two or more BB, and
  3. PPAR DR mode is enabled, and
  4. XCP Firmware version is XCP2090 or XCP2091 or XCP2092 or XCP2210.

Cause

 This problem is caused by a Hypervisor firmware bug in the PPAR DR process affecting XCP2090 thru XCP2210 firmware. 

Solution

 Workaround: 

  • Please do not use PPAR DR until upgrade to XCP2220 or later.
  • Use Inactive/Cold or System Stopped/Cold methods when performing maintenance prior to upgrading to XCP2220.

Resolution:

  • The issue is fixed in XCP2220 or later.  See Doc 1554086.1 Fujitsu M10-1/M10-4/M10-4S XSCF Control Package (XCP) Firmware Image Software Version Matrix Information

 

RTIF2-140507-002
EN0007-FNS-24217

 

References

<NOTE:1554086.1> - Fujitsu M10-1/M10-4/M10-4S XSCF Control Package (XCP) Firmware Image Software Version Matrix Information

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback