![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1677413.1 : Fujitsu M10-4S Error: Using PPAR Dynamic Reconfiguration ( DR ) on Multi Building Block Configuration May Cause Memory Corruption, OS Panic or PPAR Reset.
Applies to:Fujitsu M10-4S - Version All Versions and laterInformation in this document applies to any platform. SymptomsReleasing a system board by using Physical Partition Dynamic Reconfiguration (PPAR DR), may cause memory corruption, OS panic or Physical Partition reset (Hypervisor Abort) in the following conditions.
CauseThis problem is caused by a Hypervisor firmware bug in the PPAR DR process affecting XCP2090 thru XCP2210 firmware. Solution Workaround:
Resolution:
RTIF2-140507-002
References<NOTE:1554086.1> - Fujitsu M10-1/M10-4/M10-4S XSCF Control Package (XCP) Firmware Image Software Version Matrix InformationAttachments This solution has no attachment |
||||||||||||
|