![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1677192.1 : Post Exadata Patching Validation Error - /opt/oracle.cellos/CheckHWnFWProfile failed on one dbnode
Created from <SR 3-9065827371> Applies to:Exadata X3-2 Hardware - Version All Versions and laterInformation in this document applies to any platform. SymptomsPost patching exachk report warning : # /opt/oracle.cellos/CheckHWnFWProfile [40;1;33m[WARNING][0m The hardware and firmware does not match with the profile. See details below <Check_Result Server_Model="SUN_FIRE_X4170_M3"> <Check_Result_for_InfinibandHCA> <InfinibandHCA SIGNATURE="X4170_M2_X4270_M2_X4800_X4800_M2_X4170_M3_X4270_M3" SLOT="3"> <InfinibandHCAFirmwareVersion> <Required VALUE="2.11.2010"/> <Found VALUE="2.7.8130"/> </InfinibandHCAFirmwareVersion> </InfinibandHCA> </Check_Result_for_InfinibandHCA> </Check_Result> [40;1;33m[WARNING][0m The hardware and firmware does not match with the profile. See details above CauseHardware and firmware profile check is not successful. [Database Server] : This is because InfinibandHCAFirmwareVersion has not updated after patching. This applies to images prior to 11.2.3.3.0 which resolves bug 16392070. Solution1) Please run following command on node that node only to upgrade firmware manually : #/opt/oracle.cellos/CheckHWnFWProfile -action updatefw -component InfinibandHCA
2) If ILOM/BIOS version is not the upgraded one , we can also upgrade it manually as per following command : - Stop database/clusterware services if it is dbnode or stop cellservices if it is cellnode Attachments This solution has no attachment |
||||||||||||
|