Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1677192.1
Update Date:2015-07-03
Keywords:

Solution Type  Problem Resolution Sure

Solution  1677192.1 :   Post Exadata Patching Validation Error - /opt/oracle.cellos/CheckHWnFWProfile failed on one dbnode  


Related Items
  • Exadata X3-2 Hardware
  •  
Related Categories
  • PLA-Support>Eng Systems>Exadata/ODA/SSC>Oracle Exadata>DB: Exadata_EST
  •  




Created from <SR 3-9065827371>

Applies to:

Exadata X3-2 Hardware - Version All Versions and later
Information in this document applies to any platform.

Symptoms

Post patching exachk report warning :
===============================
Hardware and firmware profile check not is successful on one Database Server , its passed on another server :

# /opt/oracle.cellos/CheckHWnFWProfile
[40;1;33m[WARNING][0m The hardware and firmware does not match with the profile. See details below

<Check_Result Server_Model="SUN_FIRE_X4170_M3">
  <Check_Result_for_InfinibandHCA>
    <InfinibandHCA SIGNATURE="X4170_M2_X4270_M2_X4800_X4800_M2_X4170_M3_X4270_M3" SLOT="3">
      <InfinibandHCAFirmwareVersion>
        <Required VALUE="2.11.2010"/>
        <Found VALUE="2.7.8130"/>
      </InfinibandHCAFirmwareVersion>
    </InfinibandHCA>
  </Check_Result_for_InfinibandHCA>
</Check_Result>

[40;1;33m[WARNING][0m The hardware and firmware does not match with the profile. See details above
&nbsp;

Cause

Hardware and firmware profile check is not successful. [Database Server] :

This is because InfinibandHCAFirmwareVersion has not updated after patching.

This applies to images prior to 11.2.3.3.0 which resolves bug 16392070.

Solution

1) Please run following command on node that node only to upgrade firmware manually :

#/opt/oracle.cellos/CheckHWnFWProfile -action updatefw -component InfinibandHCA

Note : Please note that above command will reboot the node as part of firmware upgradation process.

 

2) If ILOM/BIOS version is not the upgraded one , we can also upgrade it manually as per following command :

- Stop database/clusterware services if it is dbnode or stop cellservices if it is cellnode
- Copy/extract patch to this node .
- Execute following steps to manually upgrade ILOM & BIOS :
- #/opt/oracle.cellos/CheckHWnFWProfile -action updatefw -mode diagnostic -component ILOM -attribute ILOMVersion -diagnostic_version "3.0.16.15.e r87097" -diagnostic_affected_attr BIOS/BIOSVersion=07060310 -fwpath <absolte path for patch .pkg file>
eg :./CheckHWnFWProfile -action updatefw -mode diagnostic -component ILOM -attribute ILOMVersion -diagnostic_version "3.0.16.15.a r73751" -diagnostic_affected_attr BIOS/BIOSVersion=07060304 -fwpath /root/Sun_Fire_X4170_X4270_X4275.pkg
- Please note that this might reboot the node . If it do not reboot automatically, reboot the node after this.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback