Solution Type Problem Resolution Sure Solution 1676851.1 : ZFS pool reported as degraded due to checksum errors on IR volume for Erie-Int.
ZFS reporting pool degraded on IR mirrored volume for Erie-INT. In this Document
Created from <SR 3-8782587331> Applies to:Sun Server X3-2L - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. SymptomsZpool FMA message: fmadm faulty
--------------- ------------------------------------ -------------- --------- TIME EVENT-ID MSG-ID SEVERITY --------------- ------------------------------------ -------------- --------- Apr 01 00:16:54 c0d289e6-a69b-4379-ce71-a2fc781666ae ZFS-8000-GH Major Problem Status : solved Diag Engine : zfs-diagnosis / 1.0 System Manufacturer : Oracle-Corporation Name : SUN-FIRE-X4270-M3 Part_Number : 32024631+1+1 Serial_Number : 1332FM5016 Host_ID : 000db8e6 ---------------------------------------- Suspect 1 of 1 : Fault class : fault.fs.zfs.vdev.checksum Certainty : 100% Affects : zfs://pool=f04be8f4f2b67459/vdev=a946a9acb26f1deb/pool_name=rpool/vdev_name=id1,sd@n600508e000000000fa7df22a1cd10403/b Status : faulted but still providing degraded service FRU Name : "zfs://pool=f04be8f4f2b67459/vdev=a946a9acb26f1deb/pool_name=rpool/vdev_name=id1,sd@n600508e000000000fa7df22a1cd10403/b" Status : faulty Description : The number of checksum errors associated with ZFS device 'id1,sd@n600508e000000000fa7df22a1cd10403/b' in pool 'rpool' exceeded acceptable levels. Response : The device has been marked as degraded. An attempt will be made to activate a hot spare if available. Impact : Fault tolerance of the pool may be compromised. Action : Use 'fmadm faulty' to provide a more detailed view of this event. Run 'zpool status -lx' for more information. Please refer to the associated reference document at http://support.oracle.com/msg/ZFS-8000-GH for the latest service procedures and policies regarding this diagnosis.
CauseZpool degraded on IR mirrored volume for Erie-INT PCI host bus adapter due to checksum errors. SolutionUse sas2ircu utility and run consistency check on IR volumes and checking status for hardware healthy. If there are no reasons reported for the checksum errors with sas2ircu or Pc-Check utility, the best further action then would be to make sure valid backup is available, purged IR volumes and create a software RAID for narrowing down the issue cause. References<NOTE:1513610.1> - MegaCli and sas2ircu - utility to manage Internal Raid HBA (LSI-Niwot /Erie)<BUG:18606812> - LSI ERIE-INT, UNABLE TO DIAGNOSE CAUSER FOR ZFS/IO ERRORS WITH SAS2IRCU UTILITY. Attachments This solution has no attachment |
||||||||||||||||||
|