Solution Type  Problem Resolution Sure

Solution  1676090.1 :   SL8500 - Rails Are Not Getting Power On New Installation  


Related Items
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  


On a new installation, no power on Rails .

In this Document
Symptoms
Cause
Solution
References


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: FE procedures outlined
Created from <SR 3-8870394037>

Applies to:

Sun StorageTek SL8500 Modular Library System - Version All Versions and later
Information in this document applies to any platform.

On a new installation, but there are no power on rails in a SL8500 library.

Symptoms

Absence of rail power or robot AC power in SL8500

Cause

Analyzed snapshot logs
I on ly see 6 power supply that are looking good the are Drives PS 1.0.0.1.1 , 1.0.0.1.2 , 1.0.0.1.21, 1.0.0.1.22 and PDU's 1.0.0.1.29 and 1.0.0.1.30
Some other power supply are present but not ok : 1.0.0.1.5, 1.0.0.1.6, 1.0.0.1.11, 1.0.0.1.12, 1.0.0.1.17, 1.0.0.1.18 , 1.0.0.1.21, 1.0.0.1.22, 1.0.0.1.23, 1.0.0.1.24, 1.0.0.1.27 and 1.0.0.1.28
Two power supply's are not seen at all from library : 1.0.0.1.25 and 1.0.0.1.26 . but they are present .
I asked to check Frond door switches..they are OK
All cable have been checked twice .
I asked to order HBN card and PDU.
I'll ask to order a HBZ module as well.
 
Cable J506 that is going from HBN card to HBLY was in short circuit with the Chassis.
This cable is installed from manufactory
 

Solution

Cable J506 that is going from HBN card to HBLY was in short circuit with the Chassis.
This cable is installed from manufacturing.

To verify the short circuit:

- Disconnect the cable from HBN card (connector P506 ) and the other site the connector that goes to HBLY LEDs.

- Check if any short between each wire.

- Check if any short between each wire and library chassis.


Replace J506 cable.
 

References

3-8870394037

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.