Asset ID: |
1-72-1675432.1 |
Update Date: | 2017-05-19 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
1675432.1
:
SL500 - IPL Failure, No Bridging Capable Drive Was Found
Related Items |
- Sun StorageTek SL500 Modular Library System
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL500 Library
|
In this Document
Created from <SR 3-9038393741>
Applies to:
Sun StorageTek SL500 Modular Library System - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.
Symptoms
Non-Bridged SL500 Library
SL500 Firmware Version: 1432 (6.89.00)
ACTUAL BEHAVIOR
---------------
SL500 IPL failure with error: No Bridging capable drive was found
SERVICE>> print log error
2014-05-22T00:32:34.744, 0.0.0.1.0, 514, robot, /usr/local/bin/Ifm, error, 0000, 0000, "Director - initResponse() Initialize: failed init of reach and grip.; End of Text"
2014-05-22T00:32:34.780, 0.0.0.0.0, 3202, ifm, , error, 0100, 3717, "IfmInitThread:Failure to Initialize...reason==Robot initialization failed - GOING INOP"
2014-05-22T04:09:18.798, 0.0.0.0.0, 3202, ifm, , error, 0100, 3722, "IfmInitThread:Failure to Initialize...reason==No Bridging capable drive was found - GOING INOP"
2014-05-22T04:23:16.341, 0.0.0.0.0, 3750, processMgr, , error, 3750, 3755, "Process /usr/local/bin/Ifm murdered by signal 11"
SERVICE>> lib getconfig
Library Configuration
Unit Type SL500
Total number of modules 1
Module 1 type 24
Total number of PTPs 0
Total number of CAPs 1
Total number of CAP cells 5
Total number of storage cells 48
Total number of reserved cells 2
Total number of tape drives 2
0,1,1,9
0,1,2,9
Total number of empty storage cells 0
Total number of restricted cells 48
Host Interface Configuration:
Interface Type: BRIDGE <- WRONG !!
Non Partition Configuration:
Partition 0
Bridge Drive Slot 0
L,M,R,C 0,1,1,9
Drive Health OK
Port A unknown
Port B unknown
Bridge Health Unavailable
Node WWN 0
Serial Number HU1018A68V
Drive Type HpUltrium4
Interface Fibre
Element Address 500
OK
From SL Console check: Interface type changed to 'Bridged'

From Command Line: disappeared FC or SCSI card
SERVICE>> lib setconfig
Interface type has no configurable parameters.
OK
EXPECTED BEHAVIOR
-----------------------
This library installed RLW card, its correct Host Interface Type should be 'SCSI' not 'BRIDGE'
BUSINESS IMPACT
-----------------------
SL500 IPL Failure
Changes
None
Cause
This is because RLW or MPU2 card fault, SL500 FW 1432 support BRIDGE mode.
RLW or MPU2 card fault and FW assumed it's Bridged library.
Solution
Replace fault RLW(or MPU2) card and reboot library.
Attachments
This solution has no attachment