![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1673851.1 : Text In Message SLS7517I Is Not Readable
VSM6 reports invalid information when DBU reaches 96% In this Document
Created from <SR 3-8839519501> Applies to:Sun StorageTek Enterprise Library Software (ELS) - Version 7.0 and laterStorageTek Virtual Storage Manager System 6 (VSM6) - Version All Versions and later IBM z/OS on System z IBM z/VM on System z This document is relevant only to VTCS environments with a VTSS model VSM6. SymptomsVSM6 reports invalid information that VTCS then outputs in error message SLS7517I when the DBU reaches over 95%. The message SLS7517I is supposed to be reporting the fact that the DBU has reached an extreme level and action needs to be taken. Instead, the error messages has invalid and sometimes unreadable information. Examples: .SLS7517I FSC running_ Help Info:
....s.......C.......s.2p....C.......u.P .SLS7517I FSC running_ Help Info: 00000090 s B/ s 2p
CauseVSM6 microcode level 6.0.6.15.000 has an error when reporting DBU over 95%. SolutionThis problem is fixed in VSM6 code level 6.0.6.16.000. Please open a hardware SR in MOS using the Hardware CSI and VSM6 Serial Number. References<BUG:18685285> - HIGH DBU SIM MESSAGES ARE REPORTING GIBBERISH IN THE TEXTAttachments This solution has no attachment |
||||||||||||||||||
|