Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1673642.1
Update Date:2015-04-28
Keywords:

Solution Type  Problem Resolution Sure

Solution  1673642.1 :   Exalogic HARDWARE FAULT: Component Error Detected. Component Name: /SYS/POWER_ATTN  


Related Items
  • Oracle Exalogic Elastic Cloud Software
  •  
  • Exadata Database Machine X2-2 Hardware
  •  
Related Categories
  • PLA-Support>Eng Systems>Exalogic/OVCA>Oracle Exalogic>MW: Exalogic Core
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-9013234291>

Applies to:

Oracle Exalogic Elastic Cloud Software - Version 1.0.0.0.0 and later
Exadata Database Machine X2-2 Hardware - Version All Versions and later
Linux x86-64
Oracle Solaris on x86-64 (64-bit)
Oracle Virtual Server(x86-64)

Symptoms

Following Hardware fault warnings are seen in the Exalogic IB Switch logs or Platinum alerts received with the following faults from IB switch

HARDWARE FAULT: Component error detected. Component Name: /SYS/POWER_ATTN

HARDWARE FAULT: Component error detected. Component Name: /SYS/CHASSIS_STATUS

 

Cause

This is a known unpublished Infiniband Switch defect:

Bug 18123353 - ADM1026 Erroneous readings of Voltage Channels even with workaround implemented

Solution

The fix of the bug 18123353 is targetted to include in Infiniband Gateway Switch Firmware update version 2.1.6.

These errors can safely be ignored if they are being seen intermittently.

To verify enviroment where the alert is seen, you can run the the following command:

root@ixl01gw02->env_test

From the generated verify the last line returns:

Environment test FAILED
root@xl01gw02->
Environment test PASSED

If this returns FAILED, then there is an issue that needs to be addressed. Please contact Oracle Exalogic Support via a new Service Request
 

References

<NOTE:1638852.1> - HARDWARE FAULT: Component Error Detected. Component Name: /SYS/CHASSIS_STATUS encountered on Exadata InfiniBand Switch
<BUG:18123353> - ADM1026 ERRONEOUS READINGS OF VOLTAGE CHANNELS EVEN WITH WORKAROUND IMPLEMENTED
<NOTE:1490235.1> - HARDWARE FAULT: Component Error Detected. Component Name: /SYS/TEMP_ATTN

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback