![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1673642.1 : Exalogic HARDWARE FAULT: Component Error Detected. Component Name: /SYS/POWER_ATTN
In this Document
Created from <SR 3-9013234291> Applies to:Oracle Exalogic Elastic Cloud Software - Version 1.0.0.0.0 and laterExadata Database Machine X2-2 Hardware - Version All Versions and later Linux x86-64 Oracle Solaris on x86-64 (64-bit) Oracle Virtual Server(x86-64) SymptomsFollowing Hardware fault warnings are seen in the Exalogic IB Switch logs or Platinum alerts received with the following faults from IB switch HARDWARE FAULT: Component error detected. Component Name: /SYS/POWER_ATTN
HARDWARE FAULT: Component error detected. Component Name: /SYS/CHASSIS_STATUS
CauseThis is a known unpublished Infiniband Switch defect: SolutionThe fix of the bug 18123353 is targetted to include in Infiniband Gateway Switch Firmware update version 2.1.6. root@ixl01gw02->env_test
From the generated verify the last line returns: Environment test FAILED
root@xl01gw02-> Environment test PASSED If this returns FAILED, then there is an issue that needs to be addressed. Please contact Oracle Exalogic Support via a new Service Request References<NOTE:1638852.1> - HARDWARE FAULT: Component Error Detected. Component Name: /SYS/CHASSIS_STATUS encountered on Exadata InfiniBand Switch<BUG:18123353> - ADM1026 ERRONEOUS READINGS OF VOLTAGE CHANNELS EVEN WITH WORKAROUND IMPLEMENTED <NOTE:1490235.1> - HARDWARE FAULT: Component Error Detected. Component Name: /SYS/TEMP_ATTN Attachments This solution has no attachment |
||||||||||||||||||
|