Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1672473.1
Update Date:2017-04-06
Keywords:

Solution Type  Problem Resolution Sure

Solution  1672473.1 :   Unable To Upgrade Firmware  


Related Items
  • Sun Fire T2000 Server
  •  
  • Sun Netra T2000 Server
  •  
  • Sun SPARC Enterprise T2000 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>CMT>SN-SPARC: Tx000
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-8925948861>

Applies to:

Sun Fire T2000 Server - Version All Versions to All Versions [Release All Releases]
Sun SPARC Enterprise T2000 Server - Version All Versions to All Versions [Release All Releases]
Sun Netra T2000 Server - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

Customer unable upgrade firmware

Cause

System firmware update fails when using sysfwdownload -u of FW 6.7.3.

Solution

Execute the sysfwdownload without using the  -u option and manually reboot the server. Reference document below " How to Update the Firmware from the OS on T1000/T2000 ".

References

<NOTE:1501504.1> - How to Update the Firmware from the OS on T1000/T2000
<NOTE:1004230.1> - Troubleshooting Firmware Upgrade Issues on a T1000/T2000

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback