![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1672473.1 : Unable To Upgrade Firmware
In this Document
Created from <SR 3-8925948861> Applies to:Sun Fire T2000 Server - Version All Versions to All Versions [Release All Releases]Sun SPARC Enterprise T2000 Server - Version All Versions to All Versions [Release All Releases] Sun Netra T2000 Server - Version All Versions to All Versions [Release All Releases] Information in this document applies to any platform. SymptomsCustomer unable upgrade firmware CauseSystem firmware update fails when using sysfwdownload -u of FW 6.7.3. SolutionExecute the sysfwdownload without using the -u option and manually reboot the server. Reference document below " How to Update the Firmware from the OS on T1000/T2000 ". References<NOTE:1501504.1> - How to Update the Firmware from the OS on T1000/T2000<NOTE:1004230.1> - Troubleshooting Firmware Upgrade Issues on a T1000/T2000 Attachments This solution has no attachment |
||||||||||||||||||
|