![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1671439.1 : Drive capacity reported by raidctl is incorrect, iostat output is still ok.
In this Document
Created from <SR 3-8871158519> Applies to:Sun Fire V215 Server - Version All Versions to All Versions [Release All Releases]Sun Fire V245 Server - Version All Versions to All Versions [Release All Releases] Sun Fire V445 Server - Version All Versions to All Versions [Release All Releases] Sun Netra T2000 Server - Version All Versions to All Versions [Release All Releases] Sun SPARC Enterprise T2000 Server - Version All Versions to All Versions [Release All Releases] Information in this document applies to any platform. SymptomsAfter upgrading to mpt patch 141743-02 (included in kernel patch 141444-09) or later, or kernel patch 141444-09, the drive capacity reported by raidctl is incorrect, iostat output is still ok. The drive is labeled correctly.
# raidctl -l -g 0.0.0 0
Disk Vendor Product Firmware Capacity Status HSP ---------------------------------- 0.0.0 FUJITSU MAY2073RCSUN72G 0401 310.9M GOOD N/A
# iostat -E sd0
sd0 Soft Errors: 2 Hard Errors: 0 Transport Errors: 0 Vendor: LSILOGIC Product: Logical Volume Revision: 3000 Serial No: Size: 73.01GB <73012215808 bytes> Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0 Illegal Request: 2 Predictive Failure Analysis: 0
CauseBug id: 6910831 and 6881276 SolutionUpdate patch 144017-01 or the latest kernel patch 142909-17. References<NOTE:1333415.1> - Sun Fire T2000 & Netra T2000 Current Product Issues<NOTE:1319798.1> - T5xx0 & earlier Hardware RAID Product Issues <BUG:6910831> - MISSING CLASS: ORACLE.PORTLET.CLIENT.PERSISTENCEIMPL.MDS.MDSTRANSFERLISTENER <BUG:6881276> - EM R2 : PLE70001GSPD: HOST UNREACHABLE Attachments This solution has no attachment |
||||||||||||||||||
|