Solution Type  Problem Resolution Sure

Solution  1671439.1 :   Drive capacity reported by raidctl is incorrect, iostat output is still ok.  


Related Items
  • Sun Fire V245 Server
  •  
  • Sun Fire V215 Server
  •  
  • Sun Fire T2000 Server
  •  
  • Sun Netra T2000 Server
  •  
  • Sun Fire V445 Server
  •  
  • Sun SPARC Enterprise T2000 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>CMT>SN-SPARC: Tx000
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-8871158519>

Applies to:

Sun Fire V215 Server - Version All Versions to All Versions [Release All Releases]
Sun Fire V245 Server - Version All Versions to All Versions [Release All Releases]
Sun Fire V445 Server - Version All Versions to All Versions [Release All Releases]
Sun Netra T2000 Server - Version All Versions to All Versions [Release All Releases]
Sun SPARC Enterprise T2000 Server - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

After upgrading to mpt patch 141743-02 (included in kernel patch 141444-09) or later, or kernel patch 141444-09, the drive capacity reported by raidctl is incorrect, iostat output is still ok. The drive is labeled correctly.

 

# raidctl -l -g 0.0.0 0
Disk Vendor Product Firmware Capacity Status HSP
----------------------------------
0.0.0 FUJITSU MAY2073RCSUN72G 0401 310.9M GOOD N/A

 

# iostat -E sd0
sd0 Soft Errors: 2 Hard Errors: 0 Transport Errors: 0
Vendor: LSILOGIC Product: Logical Volume Revision: 3000 Serial No:
Size: 73.01GB <73012215808 bytes>
Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0
Illegal Request: 2 Predictive Failure Analysis: 0

 

Cause

Bug id: 6910831 and 6881276
 

Solution

Update patch 144017-01 or the latest kernel patch 142909-17.
 

References

<NOTE:1333415.1> - Sun Fire T2000 & Netra T2000 Current Product Issues
<NOTE:1319798.1> - T5xx0 & earlier Hardware RAID Product Issues
<BUG:6910831> - MISSING CLASS: ORACLE.PORTLET.CLIENT.PERSISTENCEIMPL.MDS.MDSTRANSFERLISTENER
<BUG:6881276> - EM R2 : PLE70001GSPD: HOST UNREACHABLE