Solution Type Problem Resolution Sure Solution 1670748.1 : SFP Not Working In 16Gb FC HBA Emulex Card - WARNING: 424: Adapter warning. (SLI Port Async Event: Unsupported physical media detected)
In this Document
Created from <SR 3-8965087961> Applies to:Emulex FC HBA - Version All Versions and laterSPARC T5-8 - Version All Versions and later Information in this document applies to any platform. SymptomsSolaris 11.1.16.5.0 T5-8 server with two Dual 16Gigabit/Sec Fibre Channel / 10Gbps FCoE Host Adapter , Emulex LPe16002-M6-O Ganymede-E , Part Number 7023036 HOST NAME : server1
HOST TYPE : SPARC T5-8 HOST OS : Solaris 11.1 SPARC HOST UPTIME: 61 day(s), 22:49, 9 users, load average: 1.80, 1.25, 1.11 C# INST# PORT WWN MODEL FCODE STATUS DEVICE PATH -- ----- -------- ----- ----- ------ ----------- c8 emlxs0 4.03a1 NOT CONNECTED /pci@300/pci@1/pci@0/pci@c/SUNW,emlxs@0 c9 emlxs1 4.03a1 NOT CONNECTED /pci@300/pci@1/pci@0/pci@c/SUNW,emlxs@0,1 c10 emlxs2 4.03a1 NOT CONNECTED /pci@600/pci@1/pci@0/pci@e/SUNW,emlxs@0 c11 emlxs3 4.03a1 NOT CONNECTED /pci@600/pci@1/pci@0/pci@e/SUNW,emlxs@0,1
After inserting the new delivered SFP optics for the emulex FC HBA card these are not working as expected May 7 15:21:09 server1 emlxs: [ID 349649 kern.info] [14.14C1]emlxs3:WARNING: 424: Adapter warning. (SLI Port Async Event: Unsupported physical media detected)
May 7 15:21:09 server1 emlxs: [ID 986832 kern.warning] WARNING: emlxs3: Incompatible optics - Replace with compatible optics for card to function.
hotplug disable PCIEx
hotplug enable PCIEx
Mixing Transceiver types is not supported. Use 16Gbps SFP+ or 10Gbps SFP+.
The 10Gbps SFP+ and 16Gbps SFP+ transceivers are sold and FRU'd as pairs. Use 10Gbps Shortwave SFP+ 7023046, FRU Pair 7023057, Option 7101688. Use 16Gbps Shortwave SFP+ 7023053, FRU Pair 7023059, Option 7101686. Fibre Channel PCI Identifiers are Vendor ID 0x10df and Device ID 0xe200. Ethernet PCI Identifiers are Vendor ID 0x10df and Device ID 0xe220. FCoE PCI Identifiers are Vendor ID 0x10df and Device ID 0xe260. Vital Product Data VPD=PN is 7023036.
======================================== IO Devices =======================================
Slot + Bus Name + Model Max Speed Cur Speed Status Type Path /Width /Width ------------------------------------------------------------------------------------------- /SYS/RCSA/PCIE2 PCIE SUNW,emlxs-pciex10df,e200 7101684 8.0GT/x8 8.0GT/x8 /pci@300/pci@1/pci@0/pci@c/SUNW,emlxs@0 /SYS/RCSA/PCIE2 PCIE SUNW,emlxs-pciex10df,e200 7101684 8.0GT/x8 8.0GT/x8 /pci@300/pci@1/pci@0/pci@c/SUNW,emlxs@0,1 /SYS/RCSA/PCIE5 PCIE SUNW,emlxs-pciex10df,e200 7101684 8.0GT/x8 8.0GT/x8 /pci@600/pci@1/pci@0/pci@e/SUNW,emlxs@0 /SYS/RCSA/PCIE5 PCIE SUNW,emlxs-pciex10df,e200 7101684 8.0GT/x8 8.0GT/x8 /pci@600/pci@1/pci@0/pci@e/SUNW,emlxs@0,1
hotplug disable PCIEx May 8 08:58:00 server1 su[34226]: [ID 366847 auth.info] 'su oracle' succeeded for root on /dev/???
May 8 08:58:17 server1 genunix: [ID 408114 kern.info] /pci@300/pci@1/pci@0/pci@c/SUNW,emlxs@0/fp@0,0 (fp9) offline May 8 08:58:17 server1 genunix: [ID 408114 kern.info] /pci@300/pci@1/pci@0/pci@c/SUNW,emlxs@0/fp@0,0 (fp9) offline May 8 08:58:20 server1 genunix: [ID 408114 kern.info] /pci@300/pci@1/pci@0/pci@c/SUNW,emlxs@0 (emlxs0) offline May 8 08:58:20 server1 genunix: [ID 408114 kern.info] /pci@300/pci@1/pci@0/pci@c/SUNW,emlxs@0 (emlxs0) offline May 8 08:58:20 server1 genunix: [ID 408114 kern.info] /pci@300/pci@1/pci@0/pci@c/SUNW,emlxs@0,1/fp@0,0 (fp8) offline May 8 08:58:20 server1 genunix: [ID 408114 kern.info] /pci@300/pci@1/pci@0/pci@c/SUNW,emlxs@0,1/fp@0,0 (fp8) offline May 8 08:58:22 server1 genunix: [ID 408114 kern.info] /pci@300/pci@1/pci@0/pci@c/SUNW,emlxs@0,1 (emlxs1) offline May 8 08:58:22 server1 genunix: [ID 408114 kern.info] /pci@300/pci@1/pci@0/pci@c/SUNW,emlxs@0,1 (emlxs1) offline
hotplug enable PCIEx May 8 08:58:58 server1 emlxs: [ID 349649 kern.info] [14.0140]emlxs0: NOTICE: 200: Adapter initialization. (Networking is not supported in SLI4, turning it off) May 8 08:58:58 server1 emlxs: [ID 349649 kern.info] [14.0140]emlxs0: NOTICE: 200: Adapter initialization. (Networking is not supported in SLI4, turning it off) May 8 08:58:59 server1 emlxs: [ID 349649 kern.info] [14.14C1]emlxs0:WARNING: 424: Adapter warning. (SLI Port Async Event: Unsupported physical media detected) May 8 08:58:59 server1 emlxs: [ID 349649 kern.info] [14.14C1]emlxs0:WARNING: 424: Adapter warning. (SLI Port Async Event: Unsupported physical media detected) May 8 08:59:09 server1 emlxs: [ID 349649 kern.info] [ B.1B76]emlxs0: NOTICE: 100: Driver attach. (Emulex-S s11-64 sparc v2.90.14.0 (2013.12.07.13.30)) May 8 08:59:09 server1 emlxs: [ID 349649 kern.info] [ B.1B76]emlxs0: NOTICE: 100: Driver attach. (Emulex-S s11-64 sparc v2.90.14.0 (2013.12.07.13.30)) May 8 08:59:09 server1 emlxs: [ID 349649 kern.info] [ B.1B79]emlxs0: NOTICE: 100: Driver attach. (7101684 Dev_id:e200 Sub_id:e20e Id:48) May 8 08:59:09 server1 emlxs: [ID 349649 kern.info] [ B.1B79]emlxs0: NOTICE: 100: Driver attach. (7101684 Dev_id:e200 Sub_id:e20e Id:48) May 8 08:59:09 server1 emlxs: [ID 349649 kern.info] [ B.1B86]emlxs0: NOTICE: 100: Driver attach. (Firmware:1.1.43.8 (xe201.grp) Boot:1.1.43.8 Fcode:4.03a1) May 8 08:59:09 server1 emlxs: [ID 349649 kern.info] [ B.1B86]emlxs0: NOTICE: 100: Driver attach. (Firmware:1.1.43.8 (xe201.grp) Boot:1.1.43.8 Fcode:4.03a1) May 8 08:59:09 server1 emlxs: [ID 349649 kern.info] [ B.1BB0]emlxs0: NOTICE: 100: Driver attach. (SLI:4(FIP) MSIX:8 NPIV:0 FCA FC) May 8 08:59:09 server1 emlxs: [ID 349649 kern.info] [ B.1BB0]emlxs0: NOTICE: 100: Driver attach. (SLI:4(FIP) MSIX:8 NPIV:0 FCA FC) May 8 08:59:09 server1 emlxs: [ID 349649 kern.info] [ B.1BBE]emlxs0: NOTICE: 100: Driver attach. (WWPN:10000090FA4B4205 WWNN:20000090FA4B4205) May 8 08:59:09 server1 emlxs: [ID 349649 kern.info] [ B.1BBE]emlxs0: NOTICE: 100: Driver attach. (WWPN:10000090FA4B4205 WWNN:20000090FA4B4205) May 8 08:59:09 server1 pcieb: [ID 586369 kern.info] PCIE-device: SUNW,emlxs@0, emlxs0 May 8 08:59:09 server1 pcieb: [ID 586369 kern.info] PCIE-device: SUNW,emlxs@0, emlxs0 May 8 08:59:09 server1 genunix: [ID 936769 kern.info] emlxs0 is /pci@300/pci@1/pci@0/pci@c/SUNW,emlxs@0 May 8 08:59:09 server1 genunix: [ID 936769 kern.info] emlxs0 is /pci@300/pci@1/pci@0/pci@c/SUNW,emlxs@0 May 8 08:59:09 server1 pcieb: [ID 586369 kern.info] PCIE-device: SUNW,emlxs@0, emlxs0 May 8 08:59:09 server1 pcieb: [ID 586369 kern.info] PCIE-device: SUNW,emlxs@0, emlxs0 May 8 08:59:09 server1 genunix: [ID 408114 kern.info] /pci@300/pci@1/pci@0/pci@c/SUNW,emlxs@0 (emlxs0) online May 8 08:59:09 server1 genunix: [ID 408114 kern.info] /pci@300/pci@1/pci@0/pci@c/SUNW,emlxs@0 (emlxs0) online May 8 08:59:09 server1 emlxs: [ID 349649 kern.info] [ 5.06F0]emlxs0: NOTICE: 730: Link reset. (Resetting link...) May 8 08:59:09 server1 emlxs: [ID 349649 kern.info] [ 5.06F0]emlxs0: NOTICE: 730: Link reset. (Resetting link...) May 8 08:59:10 server1 emlxs: [ID 349649 kern.info] [ 5.073F]emlxs0: NOTICE: 730: Link reset. May 8 08:59:10 server1 emlxs: [ID 349649 kern.info] [ 5.073F]emlxs0: NOTICE: 730: Link reset. May 8 08:59:10 server1 emlxs: [ID 349649 kern.info] [14.14C1]emlxs0:WARNING: 424: Adapter warning. (SLI Port Async Event: Unsupported physical media detected) May 8 08:59:10 server1 emlxs: [ID 349649 kern.info] [14.14C1]emlxs0:WARNING: 424: Adapter warning. (SLI Port Async Event: Unsupported physical media detected) May 8 08:59:26 server1 fcsm: [ID 517869 kern.info] NOTICE: fcsm(9): attached to path /pci@300/pci@1/pci@0/pci@c/SUNW,emlxs@0/fp@0,0 May 8 08:59:26 server1 fcsm: [ID 517869 kern.info] NOTICE: fcsm(9): attached to path /pci@300/pci@1/pci@0/pci@c/SUNW,emlxs@0/fp@0,0 May 8 08:59:26 server1 genunix: [ID 936769 kern.info] fp9 is /pci@300/pci@1/pci@0/pci@c/SUNW,emlxs@0/fp@0,0 May 8 08:59:26 server1 genunix: [ID 936769 kern.info] fp9 is /pci@300/pci@1/pci@0/pci@c/SUNW,emlxs@0/fp@0,0 May 8 08:59:26 server1 genunix: [ID 408114 kern.info] /pci@300/pci@1/pci@0/pci@c/SUNW,emlxs@0/fp@0,0 (fp9) online May 8 08:59:26 server1 genunix: [ID 408114 kern.info] /pci@300/pci@1/pci@0/pci@c/SUNW,emlxs@0/fp@0,0 (fp9) online May 8 08:59:26 server1 emlxs: [ID 349649 kern.info] [14.0140]emlxs1: NOTICE: 200: Adapter initialization. (Networking is not supported in SLI4, turning it off) May 8 08:59:26 server1 emlxs: [ID 349649 kern.info] [14.0140]emlxs1: NOTICE: 200: Adapter initialization. (Networking is not supported in SLI4, turning it off) May 8 08:59:28 server1 emlxs: [ID 349649 kern.info] [14.14C1]emlxs1:WARNING: 424: Adapter warning. (SLI Port Async Event: Unsupported physical media detected) May 8 08:59:28 server1 emlxs: [ID 349649 kern.info] [14.14C1]emlxs1:WARNING: 424: Adapter warning. (SLI Port Async Event: Unsupported physical media detected) May 8 08:59:38 server1 emlxs: [ID 349649 kern.info] [ B.1B76]emlxs1: NOTICE: 100: Driver attach. (Emulex-S s11-64 sparc v2.90.14.0 (2013.12.07.13.30)) May 8 08:59:38 server1 emlxs: [ID 349649 kern.info] [ B.1B76]emlxs1: NOTICE: 100: Driver attach. (Emulex-S s11-64 sparc v2.90.14.0 (2013.12.07.13.30)) May 8 08:59:38 server1 emlxs: [ID 349649 kern.info] [ B.1B79]emlxs1: NOTICE: 100: Driver attach. (7101684 Dev_id:e200 Sub_id:e20e Id:48) May 8 08:59:38 server1 emlxs: [ID 349649 kern.info] [ B.1B79]emlxs1: NOTICE: 100: Driver attach. (7101684 Dev_id:e200 Sub_id:e20e Id:48) May 8 08:59:38 server1 emlxs: [ID 349649 kern.info] [ B.1B86]emlxs1: NOTICE: 100: Driver attach. (Firmware:1.1.43.8 (xe201.grp) Boot:1.1.43.8 Fcode:4.03a1) May 8 08:59:38 server1 emlxs: [ID 349649 kern.info] [ B.1B86]emlxs1: NOTICE: 100: Driver attach. (Firmware:1.1.43.8 (xe201.grp) Boot:1.1.43.8 Fcode:4.03a1) May 8 08:59:38 server1 emlxs: [ID 349649 kern.info] [ B.1BB0]emlxs1: NOTICE: 100: Driver attach. (SLI:4(FIP) MSIX:8 NPIV:0 FCA FC) May 8 08:59:38 server1 emlxs: [ID 349649 kern.info] [ B.1BB0]emlxs1: NOTICE: 100: Driver attach. (SLI:4(FIP) MSIX:8 NPIV:0 FCA FC) May 8 08:59:38 server1 emlxs: [ID 349649 kern.info] [ B.1BBE]emlxs1: NOTICE: 100: Driver attach. (WWPN:10000090FA4B4206 WWNN:20000090FA4B4206) May 8 08:59:38 server1 emlxs: [ID 349649 kern.info] [ B.1BBE]emlxs1: NOTICE: 100: Driver attach. (WWPN:10000090FA4B4206 WWNN:20000090FA4B4206) May 8 08:59:38 server1 pcieb: [ID 586369 kern.info] PCIE-device: SUNW,emlxs@0,1, emlxs1 May 8 08:59:38 server1 pcieb: [ID 586369 kern.info] PCIE-device: SUNW,emlxs@0,1, emlxs1 May 8 08:59:38 server1 genunix: [ID 936769 kern.info] emlxs1 is /pci@300/pci@1/pci@0/pci@c/SUNW,emlxs@0,1 May 8 08:59:38 server1 genunix: [ID 936769 kern.info] emlxs1 is /pci@300/pci@1/pci@0/pci@c/SUNW,emlxs@0,1 May 8 08:59:38 server1 pcieb: [ID 586369 kern.info] PCIE-device: SUNW,emlxs@0,1, emlxs1 May 8 08:59:38 server1 pcieb: [ID 586369 kern.info] PCIE-device: SUNW,emlxs@0,1, emlxs1 May 8 08:59:38 server1 genunix: [ID 408114 kern.info] /pci@300/pci@1/pci@0/pci@c/SUNW,emlxs@0,1 (emlxs1) online May 8 08:59:38 server1 genunix: [ID 408114 kern.info] /pci@300/pci@1/pci@0/pci@c/SUNW,emlxs@0,1 (emlxs1) online May 8 08:59:38 server1 emlxs: [ID 349649 kern.info] [ 5.06F0]emlxs1: NOTICE: 730: Link reset. (Resetting link...) May 8 08:59:38 server1 emlxs: [ID 349649 kern.info] [ 5.06F0]emlxs1: NOTICE: 730: Link reset. (Resetting link...) May 8 08:59:38 server1 emlxs: [ID 349649 kern.info] [ 5.073F]emlxs1: NOTICE: 730: Link reset. May 8 08:59:38 server1 emlxs: [ID 349649 kern.info] [ 5.073F]emlxs1: NOTICE: 730: Link reset. May 8 08:59:38 server1 emlxs: [ID 349649 kern.info] [14.14C1]emlxs1:WARNING: 424: Adapter warning. (SLI Port Async Event: Unsupported physical media detected) May 8 08:59:38 server1 emlxs: [ID 349649 kern.info] [14.14C1]emlxs1:WARNING: 424: Adapter warning. (SLI Port Async Event: Unsupported physical media detected) May 8 08:59:46 server1 sshd[34454]: [ID 800047 auth.info] Received disconnect from 10.87.168.203: 11: Session Shutdown May 8 08:59:46 server1 sshd[34559]: [ID 800047 auth.info] SSH: Server;Ltype: Version;Remote: 10.87.168.203-43663;Protocol: 2.0;Client: libssh2_1.4.3 May 8 08:59:47 server1 sshd[34559]: [ID 800047 auth.info] Accepted publickey for bmcbppm from 10.87.168.203 port 43663 ssh2 May 8 08:59:54 server1 fcsm: [ID 517869 kern.info] NOTICE: fcsm(8): attached to path /pci@300/pci@1/pci@0/pci@c/SUNW,emlxs@0,1/fp@0,0 May 8 08:59:54 server1 fcsm: [ID 517869 kern.info] NOTICE: fcsm(8): attached to path /pci@300/pci@1/pci@0/pci@c/SUNW,emlxs@0,1/fp@0,0 May 8 08:59:54 server1 genunix: [ID 936769 kern.info] fp8 is /pci@300/pci@1/pci@0/pci@c/SUNW,emlxs@0,1/fp@0,0 May 8 08:59:54 server1 genunix: [ID 936769 kern.info] fp8 is /pci@300/pci@1/pci@0/pci@c/SUNW,emlxs@0,1/fp@0,0 May 8 08:59:54 server1 genunix: [ID 408114 kern.info] /pci@300/pci@1/pci@0/pci@c/SUNW,emlxs@0,1/fp@0,0 (fp8) online May 8 08:59:54 server1 genunix: [ID 408114 kern.info] /pci@300/pci@1/pci@0/pci@c/SUNW,emlxs@0,1/fp@0,0 (fp8) online
"(SLI Port Async Event: Unsupported physical media detected)" --> this is an indication that the FC HBA recognizes SFPs as not supported
PCIE2 connected configured ok Location: PCIE2
May 8 08:58 fibre/hp n /devices/pci@300/pci@1/pci@0/pci@c:PCIE2 PCIE5 connected configured ok Location: PCIE5 May 7 15:20 fibre/hp n /devices/pci@600/pci@1/pci@0/pci@e:PCIE5
HBA Port WWN: 10000090fa4b3cbb
Port Mode: Initiator Port ID: 0 OS Device Name: /dev/cfg/c10 Manufacturer: Emulex Model: 7101684 Firmware Version: 7101684 1.1.43.8 FCode/BIOS Version: Boot:1.1.43.8 Fcode:4.03a1 Serial Number: 4925382+13340000MG Driver Name: emlxs Driver Version: 2.90.14.0 (2013.12.07.13.30) Type: unknown State: offline Supported Speeds: 4Gb 8Gb 16Gb Current Speed: not established Node WWN: 20000090fa4b3cbb Link Error Statistics: Link Failure Count: 8 Loss of Sync Count: 1258 Loss of Signal Count: 4 Primitive Seq Protocol Error Count: 0 Invalid Tx Word Count: 8352<<---??? Invalid CRC Count: 0 NPIV Not Supported HBA Port WWN: 10000090fa4b3cbc Port Mode: Initiator Port ID: 0 OS Device Name: /dev/cfg/c11 Manufacturer: Emulex Model: 7101684 Firmware Version: 7101684 1.1.43.8 FCode/BIOS Version: Boot:1.1.43.8 Fcode:4.03a1 Serial Number: 4925382+13340000MG Driver Name: emlxs Driver Version: 2.90.14.0 (2013.12.07.13.30) Type: unknown State: offline Supported Speeds: 4Gb 8Gb 16Gb Current Speed: not established Node WWN: 20000090fa4b3cbc Link Error Statistics: Link Failure Count: 0 Loss of Sync Count: 0 Loss of Signal Count: 0 Primitive Seq Protocol Error Count: 0 Invalid Tx Word Count: 0 Invalid CRC Count: 0 NPIV Not Supported HBA Port WWN: 10000090fa4b4205 Port Mode: Initiator Port ID: 0 OS Device Name: /dev/cfg/c8 Manufacturer: Emulex Model: 7101684 Firmware Version: 7101684 1.1.43.8 FCode/BIOS Version: Boot:1.1.43.8 Fcode:4.03a1 Serial Number: 4925382+13340000OG Driver Name: emlxs Driver Version: 2.90.14.0 (2013.12.07.13.30) Type: unknown State: offline Supported Speeds: 4Gb 8Gb 16Gb Current Speed: not established Node WWN: 20000090fa4b4205 Link Error Statistics: Link Failure Count: 0 Loss of Sync Count: 0 Loss of Signal Count: 0 Primitive Seq Protocol Error Count: 0 Invalid Tx Word Count: 0 Invalid CRC Count: 0 NPIV Not Supported HBA Port WWN: 10000090fa4b4206 Port Mode: Initiator Port ID: 0 OS Device Name: /dev/cfg/c9 Manufacturer: Emulex Model: 7101684 Firmware Version: 7101684 1.1.43.8 FCode/BIOS Version: Boot:1.1.43.8 Fcode:4.03a1 Serial Number: 4925382+13340000OG Driver Name: emlxs Driver Version: 2.90.14.0 (2013.12.07.13.30) Type: unknown State: offline Supported Speeds: 4Gb 8Gb 16Gb Current Speed: not established Node WWN: 20000090fa4b4206 Link Error Statistics: Link Failure Count: 0 Loss of Sync Count: 0 Loss of Signal Count: 0 Primitive Seq Protocol Error Count: 0 Invalid Tx Word Count: 25352423 <<---??? Invalid CRC Count: 0 NPIV Not Supported
When the SFPs are not supported by the FC HBA (ie third party SFPs) WARNING: emlxs0: Incompatible optics - Replace with compatible optics for card to function.
WARNING: emlxs1: Incompatible optics - Replace with compatible optics for card to function.
ChangesThe new 16GB Emulex FC HBAs were installed initially in the T5-8 server with non valid / supported SFPs. CauseThe Emulex FC HBA reads the VPD of the new SFP when the FC HBA is powered on. from Oracle Handbook. "Fibre Channel PCI Identifiers are Vendor ID 0x10df and Device ID 0xe200." This is also explained on Bug 17628896 : ILOM NEEDS TO DISTINGUISH GANYMEDE FC OR FCOE IN PCI DEVICES LIST, SUNW,emlxs (scsi-fcp, 2ac00002304) :DeviceID 0 :UnitAddress 0 :vendor-id 0x10df :device-id 0xe200 --> this shows this is FC mode :revision-id 0x10 :subsystem-vendor-id 0x10df :subsystem-id 0xe20e :class-code 0xc0400 :cache-line-size 0x10 :interrupts 00 00 00 01 :port-type PCIE-Endpoint :#vfs 0x8 :initial-vfs 0x8 :total-vfs 0x8 :first-vf-offset 0x2 :vf-stride 0x1 :fcode-rom-offset 0xfe00 :firmware-version 1.1.43.8 :fcode-version 4.03a1 :manufacture Emulex :device_type scsi-fcp emlxs driver is binded to it: :devfs-path /pci@300/pci@1/pci@0/pci@c/SUNW,emlxs@0 :driver-name emlxs :binding-name pciex10df,e200 :bus-addr 0 :instance 0 :_class scsi-fcp :name SUNW,emlxs same as correspondent fp instance: fp (devctl, 2ac00002356) :numaio-lgrps 0x1 :scsi-enumeration 0 :scsi-options 0x107ff8 :scsi-reset-delay 0xbb8 :scsi-watchdog-tick 0xa :scsi-selection-timeout 0xfa :scsi-tag-age-limit 0x2 :scsi-poll-timeout 0xa :scsi-transport-timeout 0x3c :scsi-initiator-id 0x7 :initiator-interconnect-type FABRIC :mpxio-disable no :load-ulp-list (2ac0000236aTBL) | 1 | | fcp | :scsi-binding-set fcp :class fibre-channel :port 0 :initiator-port 10000090fa4b4205 :initiator-node 20000090fa4b4205 :pm-hardware-state needs-suspend-resume :pm-components (2ac0000235fTBL) | NAME=FC Port | | 0=Port Down | | 1=Port Up | :devfs-path /pci@300/pci@1/pci@0/pci@c/SUNW,emlxs@0/fp@0,0 :driver-name fp :binding-name fp :bus-addr 0,0 :instance 9 :_class devctl :name fp Note – The transceivers must be plugged into the HBA before the HBA is booted.
The Sun Storage 16 Gb Fibre Channel PCIe Universal HBA, Emulex does not support changing the operating mode by “hot swapping” the transceivers. Note - Only supported transceivers are allowed. If invalid or unapproved transceivers are plugged in and the board is booted, the links are not allowed to come up. New FINISAR SFPs are supported with latest Universal HBA firmware 10.6.230.0 or greater, see Document ID 2119504.1 SolutionThe following commands were enough to make it working on a Solaris 11.1 T5-8 server (with the supported 16GB SFPs already installed), the removal of the FC HBA PCIE card was not necessary. hotplug disable PCIEx
cfgadm -c disconnect pciex hotplug enable PCIEx Notice, on this case, the FC HBA was already operating in FC mode (The default operating mode is two-port 16 Gb FC) On other servers, it may be required to unconfigure the cards using hotplug disable and cfgadm disconnect
NOTE. If above does not work, a Solaris server reboot may be required, read carefully all steps and possible scenarios described on page 19 and 20 "Changing the Operating Protocol Mode"
References<NOTE:1960235.1> - How To Verify Transceiver Type Installed In Oracle Sun Storage Branded Emulex 16Gb Fibre Channel / 10Gb FCoE Universal HBA On Solaris 11.2 And Later<NOTE:1581956.1> - Sun Storage 16 Gb Fibre Channel PCIe Universal Host Bus Adapter (Emulex) Operating Mode Configuration <NOTE:2119504.1> - emlxs WARNING: 424: Adapter warning. (SLI Port Async Event: Physical media not detected) Attachments This solution has no attachment |
||||||||||||||||||||
|