Solution Type
Problem Resolution Sure
Solution
1670652.1
:
WARNING: CANNOT OPEN CFG - NO SUCH CONFIG Appear In The POST Log Of The First Poweron After SP Setdefault in 8.5.0.a
Related Categories |
- PLA-Support>Sun Systems>SPARC>CMT>SN-SPARC: T4
|
In this Document
Created from <SR 3-8969851831>
Applies to:
SPARC T4-1 - Version Not Applicable to All Versions [Release N/A to All Releases]
Information in this document applies to any platform.
Symptoms
New Host Console warning messages on T4-1, T4-2, T4-4 with system firmware
8.5.0.a. Message appears only once on systems fresh from the factory. The
behavior replicates after set /SP reset_to_defaults=factory
2014-05-08 08:08:33 0:0:0> NOTICE: Storing PRI to memory
2014-05-08 08:08:34 0:0:0> WARNING: Cannot open cfg - no such config <--------------------message1
2014-05-08 08:08:34 0:0:0> NOTICE: Booting config = factory-default
2014-05-08 08:08:34 0:0:0> NOTICE: Configuring Guest MD
2014-05-08 08:08:34 0:0:0> NOTICE: Storing Guest MD to Memory
2014-05-08 08:08:34 0:0:0> NOTICE: Configuring HV MD
2014-05-08 08:08:34 0:0:0> NOTICE: Storing HV MD to Memory
2014-05-08 08:08:34 0:0:0> WARNING: Cannot open cfg - no such config <--------------------message2
2014-05-08 08:08:35 0:0:0> NOTICE: Storing Machine Descriptors to data flash
2014-05-08 08:08:35 0:0:0> NOTICE: Updating Config Information for Guest Manager
2014-05-08 08:08:35 0:0:0> NOTICE: Jumping to hypervisor
Cause
When system first boots with a blank Data Flash, because there won't be a
factory-default LDOM configuration present on the Data Flash
Solution
This only happens on the first boot and subsquent boots will not see these messages. These messages can safely be ignored.
References
<BUG:18617306> - REMOVE THE "WARNING: CANNOT OPEN CFG" HOST CONSOLE MESSAGE