![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1669359.1 : BBU Batteries Do Not Fully Charge up to 100% of Available Capacity
In this Document
Applies to:Exadata X3-2 Hardware - Version All Versions to All Versions [Release All Releases]Exadata Database Machine V2 - Version All Versions to All Versions [Release All Releases] Exadata Database Machine X2-2 Hardware - Version All Versions to All Versions [Release All Releases] Information in this document applies to any platform. SymptomsRAID controller firmware version 12.12.0-178 The battery will run charge/learn cycles approximately every two days . The battery charge may not show 100% despite a new battery being fitted.
An example below after using the command : /opt/MegaRAID/MegaCli/MegaCli64 -adpbbucmd -a0 BBU Capacity Info for Adapter: 0 Relative State of Charge: 65 % Absolute State of charge: 52 % Remaining Capacity: 791 mAh Full Charge Capacity: 1218 mAh Run time to empty: Battery is not being charged. Average time to empty: 1 Hour, 35 Min. Estimated Time to full recharge: Battery is not being charged. Cycle Count: 4 BBU Design Info for Adapter: 0 Date of Manufacture: 06/15, 2012 Design Capacity: 1500 mAh Design Voltage: 4100 mV Specification Info: 0 Serial Number: 9107 Pack Stat Configuration: 0x0000 Manufacture Name: LS36691 Firmware Version : Device Name: bq27541 Device Chemistry: LION Battery FRU: N/A Transparent Learn = 0 App Data = 0 Events log also shows charge cycles are short and more frequent compared to previous firmware versions. seqNum: 0x00001625 Time: Sun Feb 23 04:48:39 2014 Code: 0x00000093 Class: 0 Locale: 0x08 Event Description: Battery started charging Event Data: =========== None seqNum: 0x00001626 Time: Sun Feb 23 04:52:59 2014 Code: 0x000000f2 Class: 0 Locale: 0x08 Event Description: Battery charge complete Event Data: seqNum: 0x00001627 Time: Mon Mar 3 12:51:59 2014 Code: 0x00000093 Class: 0 Locale: 0x08 Event Description: Battery started charging Event Data: =========== None seqNum: 0x00001628 Time: Mon Mar 3 12:56:19 2014 Code: 0x000000f2 Class: 0 Locale: 0x08 Event Description: Battery charge complete
ChangesRAID controller firmware 12.12.0-178 CauseBattery does not need to charge to 100%, it will only charge to mAh needed for 2 days of data retention. As battery ages, this percentage will get larger. This allows the unused battery to age slower. SolutionDefault behaviour with firmware 12.12.0-178 Attachments This solution has no attachment |
||||||||||||||||||
|