Created from <SR 3-8917346531> Applies to:Sun Enterprise 450 Server - Version All Versions to All Versions [Release All Releases]Oracle Solaris on SPARC (64-bit) SymptomsThe server reports a fan failure that appears to be related to a power supply and then the server shuts down. WARNING: Power supply fan 1 failure detected
Environmental monitor is authorized to shut down your system. WARNING: Fan Fail is 0xfd retries = 3 WARNING: PS Fan Number 1 Failed WARNING Fan Failure(s), System shutdown. CauseAlthough one can assume that the power supply would contain the faulty fan in question, this is not the case. This fault actually involves a fan on the disk fan assembly. The disk fan assembly serves both the disks and the power supplies. SolutionIf a server has experienced a shutdown due to this fault, please open a service request with Oracle Support.
If the fault has been confirmed, the disk fan assembly should be replaced. Attachments This solution has no attachment |
||||||||||||||||
|