![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 1664043.1 : SL3000/LTO6 - Media Write Errors, Encryption Error - 112A
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:IBM LTO6 Tape Drive - Version All Versions and laterSun StorageTek SL3000 Modular Library System - Version All Versions and later Information in this document applies to any platform. SymptomsOn new tape is airing out media write errors. No new keys are being presented 37 15 64d 04h:21m:17s 366271286 2762022 366271286 D8E6 (tf130814f) IMATION 37055960 0 e: Encryption Error 112A: Encryption,KeyService Timeout 0000: No Error Detected CauseCurrently running a configuration that is not supported and is known not to work at this time. SolutionNeed to take the Bel cards back to LDI mode until the SL3000 code is released to support ADI mode on Bel cards. Once this was done, the problem should be resolved. Attachments This solution has no attachment |
||||||||||||||||
|