![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1663518.1 : Exalytics: Running "Summary Advisor" In Administration Tool Fails With 'Check Database Specific Features Table. Must Be Able To Push At Least A Single Table Reference To A Remote Database'
In this Document
Created from <SR 3-8815493311> Applies to:Oracle Exalytics Software - Version 1.0.0.0.0 and laterExalytics In-Memory Machine X3-4 - Version All Versions and later Exalytics In-Memory Machine X2-4 - Version All Versions and later Business Intelligence Server Administrator - Version 11.1.1.6.2 and later Business Intelligence Suite Enterprise Edition - Version 11.1.1.6.2 and later Information in this document applies to any platform. SymptomsYou have intergrated Times Ten 11.2.2.4.5 with OBIEE 11.1.1.6.2. However, while executing "Summary Advisor" it fails with the below error: [NQODBC] [SQL_STATE: HY000] [nQSError: 10058] A general error has occurred.
CauseCause of this issue has been identified and verified as
SolutionTo fix this issue, Increase the value of MAX_TABLES_IN_SELECT for Tracking database in the Features tab in repository (RPD). References<BUG:18597346> - EXALYTICS:ERROR WHEN EXECUTE "SUMMARY ADVISOR" IN ADMIN TOOL [NQSERROR: 42016]Attachments This solution has no attachment |
||||||||||||||||||
|