Solution Type Problem Resolution Sure Solution 1663140.1 : Oracle ZFS Storage: What changes are required to the Active Directory service when the admin password is changed, system software is upgraded or takeover/failback is executed?
In this Document
Created from <SR 3-8840703081> Applies to:Sun ZFS Backup Appliance - Version All Versions to All Versions [Release All Releases]Sun ZFS Storage 7420 - Version All Versions to All Versions [Release All Releases] Oracle ZFS Storage ZS3-2 - Version All Versions to All Versions [Release All Releases] Oracle ZFS Storage ZS3-4 - Version All Versions to All Versions [Release All Releases] Sun ZFS Storage 7320 - Version All Versions to All Versions [Release All Releases] 7000 Appliance OS (Fishworks) SymptomsWe have received several requests for information on whether any proactive steps are required, e.g. rejoining the AD domain, switching to workgroup mode, restarting service when the following operations are performed:
CauseIncorrect information.
SolutionNo proactive steps are required in any of the above cases. None of the above actions should result in a loss of connectivity to the AD domain. However, note that during an upgrade or takeover, if a stripped head is left without network interfaces (which goes against best practices), it will be unable to contact the domain until failback is completed.