Asset ID: |
1-72-1645042.1 |
Update Date: | 2015-03-16 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
1645042.1
:
Exadata: HC-Disk Failure On Storage Cell X
Related Items |
- Exadata Database Machine X2-2 Hardware
- Exadata Database Machine X2-2 Hardware
|
Related Categories |
- PLA-Support>Eng Systems>Exadata/ODA/SSC>Oracle Exadata>DB: Exadata_EST
|
Created from <SR 3-8805852921>
Applies to:
Exadata Database Machine X2-2 Hardware
Information in this document applies to any platform.
Symptoms
Disk Failure on Storage Cell 7 , Disk Dropped, No alert in alerthistory.
=================================================================================================================
name: exprceladm07
cellVersion: OSS_11.2.3.2.0_LINUX.X64_120713
id: 1228FMM0DX
makeModel: Oracle Corporation SUN FIRE X4270 M2 SERVER SAS
releaseVersion: 11.2.3.2.0
upTime: 0 days, 0:53
=================================================================================================================
Issue Description: Disk Failure on Storage Cell 7 , Disk Dropped
=================================================================================================================
name: 20:11
deviceId: 8
diskType: HardDisk
enclosureDeviceId: 20
errMediaCount: 0
errOtherCount: 0
foreignState: false
luns: 0_11
makeModel: "HITACHI HUS1560SCSUN600G"
physicalFirmware: A6C0
physicalInsertTime: 2012-12-06T17:04:22+05:30
physicalInterface: sas
physicalSerial: KK1MPM
physicalSize: 558.9109999993816G
slotNumber: 11
status: warning - poor performance
name: 0_11
cellDisk: CD_11_exprceladm07
deviceName: /dev/sdl
diskType: HardDisk
id: 0_11
isSystemLun: FALSE
lunAutoCreate: FALSE
lunSize: 557.861328125G
lunUID: 0_11
physicalDrives: 20:11
raidLevel: 0
lunWriteCacheMode: "WriteBack, ReadAheadNone, Direct, No Write Cache if Bad BBU"
status: warning - poor performance
Cause
An alert for disks in 'poor performance' state should be generated. There are several different reasons a disk may enter this state, the cause may be down-rev firmware or image or some other event.
Solution
A sundiag.sh should be collected and uploaded for review to determine if this is being caused by a software failure or hardware failure, and what the appropriate action plan should be.
References
<NOTE:1326611.1> - Things to Check in ASM When Replacing an ONLINE disk from Exadata Storage Cell
<NOTE:166650.1> - Working Effectively With Oracle Support - Best Practices
<NOTE:761868.1> - Oracle Exadata Diagnostic Information required for Disk Failures and some other Hardware issues
Attachments
This solution has no attachment