![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1642480.1 : Repeatedly getting SPX86-8002-VP "fault.chassis.device.misconfig" error even after clearing logs and restting SP
In this Document
Created from <SR 3-8563428481> Applies to:Sun Fire X4470 Server - Version All Versions to All Versions [Release All Releases]Oracle Solaris on x86-64 (64-bit) SymptomsTo discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community - Sun x86 Systems
Repeatedly getting the following error message: Class fault.chassis.device.misconfig Message ID SPX86-8002-VP Component /SYS/SP CauseThe fault is raised because of monitoring tools that access the SP and monitor the hardware , in this case OHMP 2.1 is installed. This can fill up /var/logs. Clearing the ILOM logs, resetting the ILOM does not resolve the issue, the var/log file gets filled up again within a week. SolutionThe issue is resolved by removing older version of OHMP and installing the latest version of OHMP. This is not a hardware fault with Service Processor and no hardware needs to be replaced. References<NOTE:1180190.1> - SPX86-8002-VP - The /var/log filesystem has exceeded the filesystem capacity limit.<NOTE:1394673.1> - ILOM Incorrectly Reports Failure When No Fault Exists: Error: "fault = fault.chassis.device.misconfig@/sys/sp" <BUG:7030133> - ADMIN:SECURITY:USERS: GIVES ERROR: CANNOT RETRIEVE METADATA Attachments This solution has no attachment |
||||||||||||||||||
|