Symptoms

To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community - Sun x86 Systems

Repeatedly  getting the following error message:

Class fault.chassis.device.misconfig
Message ID SPX86-8002-VP
Component /SYS/SP

Cause

The fault is raised because of monitoring tools that access the SP and monitor the hardware , in this case OHMP 2.1 is installed.  This can fill up /var/logs.

Clearing the ILOM logs, resetting the ILOM does not resolve the issue, the var/log file gets filled up again within a week.
 

Solution

The issue is resolved by removing older version of OHMP and installing the latest version of OHMP.

This is not a hardware fault with Service Processor and no hardware needs to be replaced.

References

<NOTE:1180190.1> - SPX86-8002-VP - The /var/log filesystem has exceeded the filesystem capacity limit.
<NOTE:1394673.1> - ILOM Incorrectly Reports Failure When No Fault Exists: Error: "fault = fault.chassis.device.misconfig@/sys/sp"
<BUG:7030133> - ADMIN:SECURITY:USERS: GIVES ERROR: CANNOT RETRIEVE METADATA

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback