Asset ID: |
1-72-1641955.1 |
Update Date: | 2017-09-05 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
1641955.1
:
SL500/LTO - Result Code 3318 LOAD DRIVE: (LMRC) x,x,x,x Request Failed
Related Items |
- Sun StorageTek SL500 Modular Library System
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL500 Library
|
In this Document
Created from <SR 3-8775811191>
Applies to:
Sun StorageTek SL500 Modular Library System - Version All Versions to All Versions [Release All Releases] Information in this document applies to any platform.
Symptoms
SL500 Tape Library takes all four tape drive units off-line and reports a Robotic Arm Error. Tried rebooting from the SLC as well as powering the unit off and initializing the stack after the inventory is complete but still get the Robotic Arm Error when started a backup job.
2014-03-31 10:52:18 |
Drive_Bay2(0,1,2,9)
3318 - (14X)
(request id = HOST/0x1025b478) IfmMove::commonMoveCommand(): LOAD DRIVE: (LMRC) 0,1,2,9 request failed:
000411L4 (x6)
(Errors Started - 2014-03-18 15:01:43 Errors Stopped - 2014-03-31 10:52:18)
|
2014-03-31 09:36:53 |
Drive_Bay4(0,2,2,9)
0000 - (1X)
(request id = UNKNOWN/0) IfmMove::unloadDrive():Drive reporting 'empty' after UNLOAD (over-eject) on: (LMRC) 0,2,2,9
(Errors Started - 2014-03-19 16:40:00 Errors Stopped - 2014-03-19 16:40:00)
3318 - (7X)
(request id = HOST/0x1025b478) IfmMove::commonMoveCommand(): LOAD DRIVE: (LMRC) 0,2,2,9 request failed:
000411L4 (x3)
(Errors Started - 2014-03-18 15:22:07 Errors Stopped - 2014-03-31 09:36:53)
|
2014-03-28 16:03:04 |
Drive_Bay3(0,2,1,9)
3318 - (17X)
(request id = HOST/0x1025b478) IfmMove::commonMoveCommand(): LOAD DRIVE: (LMRC) 0,2,1,9 request failed:
000411L4 (x11)
(Errors Started - 2014-03-18 08:45:34 Errors Stopped - 2014-03-28 16:03:04)
|
2014-03-26 10:44:58 |
Drive_Bay1(0,1,1,9)
3318 - (5X)
(request id = HOST/0x1025b478) IfmMove::commonMoveCommand(): LOAD DRIVE: (LMRC) 0,1,1,9 request failed:
000411L4 (x1)
(Errors Started - 2014-03-18 04:50:19 Errors Stopped - 2014-03-26 10:44:58)
|
Changes
No changes
Cause
Bad cartridge 000411L4 which cause all loading failed for 4 different tape drive in the SL500.
Solution
Remove media ID 000411L4 from the SL500, and no more problem with SL500 robotic arm.
Attachments
This solution has no attachment
|