Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1641405.1
Update Date:2017-05-19
Keywords:

Solution Type  Problem Resolution Sure

Solution  1641405.1 :   SL150 - Reporting No Boot Device Detected  


Related Items
  • StorageTek SL150 Modular Tape Library
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL150 Library
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-8746048536>

Applies to:

StorageTek SL150 Modular Tape Library - Version All Versions and later
Information in this document applies to any platform.

Symptoms

SL150 reports "No boot device detected. Please hit any key to reboot!" on the OP panel.

SL150 will not boot all the way so unable to collect logs.

 

Cause

Faulty robotic module.

Solution

A replacement robotics module will need to be ordered.

7023260 [C] Robot Module

Always check for the latest Part Number for the assembly.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback