Inactivity timeout of  SL8500 operator panel is too short with FRS 8.xx

In this Document
Symptoms
Changes
Cause
Solution
References


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for Service Personnel
Created from <SR 3-8722271058>

Applies to:

Sun StorageTek Framework Library Monitor Software - Version 4.3 and later
Sun StorageTek SL8500 Modular Library System - Version All Versions and later
Information in this document applies to any platform.

Symptoms

 Users get automatically logged off the SL8500 operator panel when the inactivity timer is expired as a security feature. Some user find this annoying and want to get rid of this feature.

Changes

 This happens with FRS version 8.xx and higher on an SL8500

Cause

 Firmware feature

Solution

There is a CLI command to modify the pliAuthentification timeout value.

From a "service" login enter

SL8500>    config pliAuth  set [6,24,48,72,168)

(choose timeout value hours )

Some customers will accept a higher timeout value than the default 6 hours.

References