![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1641019.1 : SL8500 - Inactivity Timeout of SL8500 Operator Panel is Too Short With FRS 8.xx
Inactivity timeout of SL8500 operator panel is too short with FRS 8.xx In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:Sun StorageTek Framework Library Monitor Software - Version 4.3 and laterSun StorageTek SL8500 Modular Library System - Version All Versions and later Information in this document applies to any platform. SymptomsUsers get automatically logged off the SL8500 operator panel when the inactivity timer is expired as a security feature. Some user find this annoying and want to get rid of this feature. ChangesThis happens with FRS version 8.xx and higher on an SL8500 CauseFirmware feature SolutionThere is a CLI command to modify the pliAuthentification timeout value. From a "service" login enter SL8500> config pliAuth set [6,24,48,72,168) (choose timeout value hours ) Some customers will accept a higher timeout value than the default 6 hours. References<NOTE:1511569.1> - SL500/SL3000/SL8500 - How to Download the SLConsole (SLC)Attachments This solution has no attachment |
||||||||||||||||||||
|