Solution Type Problem Resolution Sure Solution 1638852.1 : HARDWARE FAULT: Component Error Detected. Component Name: /SYS/CHASSIS_STATUS encountered on Exadata InfiniBand Switch
Created from <SR 3-8739186641> Applies to:Sun Datacenter InfiniBand Switch 36 - Version All Versions and laterExadata Database Machine X2-2 Hardware - Version All Versions and later Oracle Exalogic Elastic Cloud Software - Version 2.0.6.0.0 to 2.0.6.0.0 Information in this document applies to any platform. SymptomsEncountered the following event on Exadata InfiniBand Switch: HARDWARE FAULT: Component error detected. Component Name: /SYS/CHASSIS_STATUS
CauseCollect an ILOM snapshot (<Note 1062544.1>) from the InfiniBand Switch and check if shows faulty. If there are no faults then run the below commands and check if the Environment test PASSED and switch is healthy: # env_test
# showunhealthy # sminfo # getmaster If there is no indication of fault visible in env_test or in showunhealthy output then you seem to hit unpublished Bug: 18123353. SolutionThis errors can be safely ignored. Fix for this problem is included in firmware 2.1.6. Exadata Storage Server software 11.2.3.3.0 includes InfiniBand switch firmware release 2.1.3-4 and hence the fix is not present. References<BUG:18123353> - ADM1026 ERRONEOUS READINGS OF VOLTAGE CHANNELS EVEN WITH WORKAROUND IMPLEMENTEDAttachments This solution has no attachment |
||||||||||||
|