Symptoms

The following Event is generated by the Slammer:

2014-03-14T07:16:15.520     INFORMATIONAL   PSG_DMS_EVENT_MA_LOCSW               /Slammer1/1    /Slammer1/1

Cause

This event occurs when the Management Locator Switch, labeled "ACK", on the back of the Ax600 slammer is depressed.  By itself, the problem is harmless but should be resolved to clear the event.

 The original purpose was to be used as a way to identify a system, but this functionality was never implemented.

The recessed ACK button is located on the upper left side of the PIM (Private Interface Module) just to the right of the recessed PWR button.

 PIM_ACK

 

PIM Board,  Internal view of ACK or Management Locator Switch.

 

PIM_ACK_BOARD

 

Event Properties

EVENT

Event Logs Screen

EVENT_LOG

Solution

Possible causes:

  1. ACK button may have inadvertently been depressed.
  2. Private Interface Module.
  3. The Slammer Motherboard:
    1. Bent pin
    2. Damage component
    3. SIO (SCSI IO) chip


Identify and replace the proper component.