![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 1637705.1 : Pillar Axiom: Deprecated Management Locator Switch on the Back of the Slammer Generates the Informational Event "PSG_DMS_EVENT_MA_LOCSW"
In this Document
Created from <SR 3-8200134666> Applies to:Pillar Axiom 600 Storage System - Version Not Applicable to Not Applicable [Release N/A]Information in this document applies to any platform. SymptomsThe following Event is generated by the Slammer: 2014-03-14T07:16:15.520 INFORMATIONAL PSG_DMS_EVENT_MA_LOCSW /Slammer1/1 /Slammer1/1 CauseThis event occurs when the Management Locator Switch, labeled "ACK", on the back of the Ax600 slammer is depressed. By itself, the problem is harmless but should be resolved to clear the event. The recessed ACK button is located on the upper left side of the PIM (Private Interface Module) just to the right of the recessed PWR button.
PIM Board, Internal view of ACK or Management Locator Switch.
Event Properties Event Logs Screen SolutionPossible causes:
Attachments This solution has no attachment |
||||||||||||||||
|