Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1636612.1
Update Date:2015-08-18
Keywords:

Solution Type  Problem Resolution Sure

Solution  1636612.1 :   RMLS - BRMS Drive Mount Fails When Running a Full System Restricted Save  


Related Items
  • Sun StorageTek T10000A Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Symptoms
Changes
Cause
Solution


Created from <SR 3-8682037181>

Applies to:

Sun StorageTek T10000A Tape Drive - Version All Versions and later
Information in this document applies to any platform.

Symptoms

Full system save fails with error CPF9999, message ID RE00060 un-monitored.

Changes

 New RMLS Install or Operating System Upgrade.

Cause

BRMS (Backup Recovery and Media Services) User Defined Media Library needs to be updated with correct RMLS command - CALL RMLS/ALCBRMDEV PARM(&DEVICE).

Solution

From the iSeries run following commands:
wrkdevbrm
Select option 2 to change media library.
Change the following command to be:
Allocate device command . . . . . . . . . . . . . CALL RMLS/ALCBRMDEV PARM(&DEVICE)
 


Attachments
This solution has no attachment