Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1635621.1
Update Date:2017-05-22
Keywords:

Solution Type  Problem Resolution Sure

Solution  1635621.1 :   SL150 - Power Supply Communication Error  


Related Items
  • StorageTek SL150 Modular Tape Library
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL150 Library
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-8609376448>

Applies to:

StorageTek SL150 Modular Tape Library - Version All Versions and later
Information in this document applies to any platform.

Symptoms

The module controller has lost communication with the power supply.

O,0022,2014-02-27T01:17:33.535,9015,PS_COMMUNICATION_ERROR,1,Module 1 Top PowerSupply,2,Robot,3,Module 1 Motherboard,,,,,Unplug and reinsert both AC and Power Supplies. Reseat/replace controller. Replace power supply.

2014-02-27 01:17:33
0022 - PS_COMMUNICATION_ERROR - Fault Code:9015
Probable Failed Components
1. Module 1 Top PowerSupply
2. Robot
3. Module 1 Motherboard

Cause

Defective power supply.

Solution

Actions to Take
Unplug and reinsert both AC and Power Supplies.
Reseat/replace controller.
Replace power supply.

Replaced Power Supply to resolve issue.

7050301 [C] 155 Watt Power Supply
SL150 - How to Remove/Replace a Power Supply CRU on the StorageTek SL150 Modular Tape Library:ATR:1473762.1:0 (Doc ID 1473762.1)

 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback