Solution Type Problem Resolution Sure Solution 1635539.1 : SL8500/SL3000 - Persistence Manager Error Cartridge Manager.addCartridges
This KB is about the error Summary:3237: "Persistence Manager error CartridgeManager.addCartridges(StkCartridge[] Funded on the 8+ code on the sl8500, 4+ code sl3000 In this Document
Applies to:Sun StorageTek SL8500 Modular Library System - Version Not Applicable to Not Applicable [Release N/A]Sun StorageTek SL3000 Modular Library System - Version Not Applicable to Not Applicable [Release N/A] Information in this document applies to any platform. This KB is about the error Summary:3237: "Persistence Manager error CartridgeManager.addCartridges(StkCartridge)] Funded on the 8+ code on the SL8500, 4+ code SL3000. SymptomsError message Presented in Logs: Persistence Manager error CartridgeManager.addCartridges(StkCartridge[] cartridges), there was a problem while updating database ", exception=Aborting the #EMPTY cartridge into the database at 3,4,6,1,1; CauseThe error represents a failure from the library to update the Data Base at a given moment. This informational message has been put in to prevent Data Base corruption. SolutionThis Error does not represent any failure by itself. Library should recover and continue to access the Data Base normally.