Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1635390.1
Update Date:2014-05-13
Keywords:

Solution Type  Problem Resolution Sure

Solution  1635390.1 :   Sun Storage 7000 Unified Storage System: 7310 Array Will Not Boot  


Related Items
  • Sun Storage 7310 Unified Storage System
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>ZFS Storage>SN-DK: 7xxx NAS
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-8667760121>

Applies to:

Sun Storage 7310 Unified Storage System - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

After poweroff of array subsequent poweron boot displayed the following messages:

WARNING: Could not find expander device.
Error encountered during stage4.
Configuration information maybe invalid.
Rollback from GRUB menu.
Contact your authorized support resource.

Then the array dropped to the bash prompt.

Monitoring the serial port during a power cycle event shows no service processor boot messages.

There is no net management connectivity.

Cause

It was found that the service processor was faulty.

The system bios could not obtain the needed configuration information from the service processor.

Solution

 The motherboard was replaced as the service processor is on the motherboard with the replacement process followed.

Array booted ok after motherboard replaced.

References

<NOTE:1400710.1> - Sun ZFS Storage Appliance: How to perform SP reset from BUI/CLI

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.