Solution Type  Problem Resolution Sure

Solution  1634938.1 :   SL8500 - Media Validation Error Being Reported in SL Console  


Related Items
  • Sun StorageTek SL8500 Modular Library System
  •  
  • StorageTek T10000D Tape Drive
  •  
  • StorageTek T10000C Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  




In this Document
Symptoms
Cause
Solution


Applies to:

Sun StorageTek SL8500 Modular Library System - Version All Versions and later
StorageTek T10000D Tape Drive - Version All Versions and later
StorageTek T10000C Tape Drive - Version All Versions and later
Information in this document applies to any platform.

Symptoms

Active SL Console media validation session is interrupted by a host request for the associated cartridge.  SL Console indicates the media validation has stopped but does not allow the user to start another media validation.  The SL Console media validation appears to be hung.

Example of what will be seen in the SL Console validation progress window:

-------------------------------------------------

standardVerify  Cart: RWB212T2  Drive: 1,3,-1,1,1

Date : 02/20/2014     Time : 11:07:32

-------------------------------------------------

11:07:32 Retrieving and mounting cartridge

11:07:54 Validation progress - 0%

11:09:06 Validation progress - 16%

11:09:22 Please wait...Stopping validation, dismounting cartridge and returning to source.

11:11:35 Drive reported that Media Validation is finished

11:11:35 Media validation completion status: success (16% complete when validation interrupted)

A SLC refresh clears the validation progress window, and the Start button is made active, but you can't select a different validation type.  In this case, the only way to recover is to log out of SLC then log back in.

If a refresh is not done, the Stop button is active, but an error pops up.

SLC screen shot; hang after the host media request interrupted the media validation.

HostInterruptedSLCInitiatedMV

HostInterruptedSLCInitiatedMV 

Then, if you select the stop button, the 2nd screen shot shows the error that pops up.

UseStopButtonToClearSLC

 UseStopButtonToClearSLC

The last screen shot shows what the media validation progress area looks like after closing the error pop up.

AfterClosingError

 AfterClosingError

 

Cause

 SL8500 code error at 8.35.

Solution

 This issue will be addressed in upcoming code release.  Fix targeted for 8.50, August, 2015.