![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 1634938.1 : SL8500 - Media Validation Error Being Reported in SL Console
In this Document
Applies to:Sun StorageTek SL8500 Modular Library System - Version All Versions and laterStorageTek T10000D Tape Drive - Version All Versions and later StorageTek T10000C Tape Drive - Version All Versions and later Information in this document applies to any platform. SymptomsActive SL Console media validation session is interrupted by a host request for the associated cartridge. SL Console indicates the media validation has stopped but does not allow the user to start another media validation. The SL Console media validation appears to be hung. Example of what will be seen in the SL Console validation progress window: ------------------------------------------------- standardVerify Cart: RWB212T2 Drive: 1,3,-1,1,1 Date : 02/20/2014 Time : 11:07:32 ------------------------------------------------- 11:07:32 Retrieving and mounting cartridge 11:07:54 Validation progress - 0% 11:09:06 Validation progress - 16% 11:09:22 Please wait...Stopping validation, dismounting cartridge and returning to source. 11:11:35 Drive reported that Media Validation is finished 11:11:35 Media validation completion status: success (16% complete when validation interrupted) A SLC refresh clears the validation progress window, and the Start button is made active, but you can't select a different validation type. In this case, the only way to recover is to log out of SLC then log back in. If a refresh is not done, the Stop button is active, but an error pops up. SLC screen shot; hang after the host media request interrupted the media validation. HostInterruptedSLCInitiatedMV
Then, if you select the stop button, the 2nd screen shot shows the error that pops up. UseStopButtonToClearSLC The last screen shot shows what the media validation progress area looks like after closing the error pop up. AfterClosingError
CauseSL8500 code error at 8.35. SolutionThis issue will be addressed in upcoming code release. Fix targeted for 8.50, August, 2015. Attachments This solution has no attachment |
||||||||||||||||
|