Solution Type  Problem Resolution Sure

Solution  1634327.1 :   SL24/SL48 - On OCP Error Code B2 03  


Related Items
  • Sun StorageTek SL48 Tape Library
  •  
  • Sun StorageTek SL24 Tape Autoloader
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: OEM Drive and Library
  •  




In this Document
Symptoms
Changes
Cause
Solution
References


Created from <SR 3-8679984073>

Applies to:

Sun StorageTek SL24 Tape Autoloader - Version All Versions and later
Sun StorageTek SL48 Tape Library - Version All Versions and later
Information in this document applies to any platform.

Symptoms

Customer see on OCP (Operator Control Panel) the error Code B2 03.

 

Changes

 

Cause

B2 Communication to robot from Autoloader or Library controller failed.

03 Error motor initialization.

Solution

Update the firmware to the latest version.
Power cycle the device and retry the operation.

If this does not resolve issue, replace SL24/SL48 Chassis.
 

References

<NOTE:1019631.1> - SL24/48 - Where to Find Error Code Information for Libraries

Attachments
This solution has no attachment