Solution  1633127.1 :   SL150 - Error on Front Panel of the Tape Library/ Health Status Degraded  


Related Items
  • StorageTek SL150 Modular Tape Library
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL150 Library
  •  




In this Document
Symptoms
Changes
Cause
Solution
References


Created from <SR 3-8651234447>

Applies to:

StorageTek SL150 Modular Tape Library - Version All Versions and later
Information in this document applies to any platform.

Symptoms

Error in front panel of the tape library.
Library health status degraded.

Amber LED

Changes

 No recent changes

Cause

0197 - PS_COMMUNICATION_ERROR - Fault Code:9015
 
No hardware faults observed from library logs.
 

Solution

After power cycling the library it has come online.

Action Plan:

Power cycle the library.

If still issue:

Unplug and reinsert both AC and Power Supplies.

Reseat/replace controller.

Replace power supply.
 

References

<NOTE:1474118.1> - SL150 - How to Generate and Retrieve a Service Bundle (Health / Error Log) From the StorageTek SL150 Modular Tape Library