Solution Type Problem Resolution Sure Solution 1632562.1 : SL150 - Tapes Are Showing As Unreadable
In this Document
Created from <SR 3-8398357164> Applies to:StorageTek SL150 Modular Tape Library - Version All Versions and laterInformation in this document applies to any platform. SymptomsUnreadable cleaning cartridge label on 2 different SL150, after customer add in the new cleaning cartridge. From SL150 log SL150_xxxxxxx_xxxxxxx_Wed_Jan_15_2014_GMT_13_10_23_logs.tar.gz 2014-01-13T10:37:14.127, 0.0.0.0.0, 3200, ifm, , info, 0000, 3300, "IFM cartridge with unreadable label at: (P:MSRC) 0:10,R,1,2 "
2014-01-13T10:37:51.227, 0.0.0.0.0, 3200, ifm, , info, 0000, 3300, "IFM cartridge with unreadable label at: (P:MSRC) 0:10,R,2,2 " 2014-01-13T10:38:27.750, 0.0.0.0.0, 3200, ifm, , info, 0000, 3300, "IFM cartridge with unreadable label at: (P:MSRC) 0:10,R,3,2 "
2014-01-15T08:42:11.881, 0.0.0.0.0, 3200, ifm, , info, 0000, 3300, "IFM cartridge with unreadable label at: (P:MSRC) 0:10,R,1,4 "
2014-01-15T08:42:48.881, 0.0.0.0.0, 3200, ifm, , info, 0000, 3300, "IFM cartridge with unreadable label at: (P:MSRC) 0:10,R,2,4 " 2014-01-15T08:43:26.390, 0.0.0.0.0, 3200, ifm, , info, 0000, 3300, "IFM cartridge with unreadable label at: (P:MSRC) 0:10,R,3,4 "
ChangesAdding new cleaning cartridges to library. CauseThe bar code shall be on the Hub side of the cartridge when installed. The human readable characters will be to the top side of the cartridge (opposite the hub). The cleaning cartridge label barcode of this customer is not on the correct side. SolutionCustomer reprinted the barcode according to specification in the barcode document. References<NOTE:1514925.1> - SL150 - Cannot Read The Media Label In Mail Slot #2 And #3Attachments This solution has no attachment |
||||||||||||||||||||
|