![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1632249.1 : Exachk Execution Reports Some Skipped Checks
In this Document
Created from <SR 3-8578133111> Applies to:Exadata Database Machine X2-2 Hardware - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. SymptomsExachk may skip some checks Infiniband Switch (can also be other checks) Examples: skipping Infiniband switch HOSTNAME configuration (checkid:- 9AD56124DDFE9FCCE040E50A1EC038A6) on dm01sw-ib3 because s_sysconfig_network_dm01sw-ib3.out not found
skipping Infiniband switch HOSTNAME configuration (checkid:- 9AD56124DDFE9FCCE040E50A1EC038A6) on dm01sw-ib2 because s_sysconfig_network_dm01sw-ib2.out not found skipping Infiniband switch HOSTNAME configuration (checkid:- 9AD56124DDFE9FCCE040E50A1EC038A6) on dm01sw-ib3 because s_sysconfig_network_dm01sw-ib3.out not found skipping Infiniband switch HOSTNAME configuration (checkid:- 9AD56124DDFE9FCCE040E50A1EC038A6) on dm01sw-ib2 because s_sysconfig_network_dm01sw-ib2.out not found skipping Infiniband Switch NTP configuration (checkid:- 9AD59DE0898D0513E040E50A1EC03EEA) on dm01sw-ib3 because s_ntp_dm01sw-ib3.out not found skipping Infiniband Switch NTP configuration (checkid:- 9AD59DE0898D0513E040E50A1EC03EEA) on dm01sw-ib2 because s_ntp_dm01sw-ib2.out not found skipping Infiniband Switch NTP configuration (checkid:- 9AD59DE0898D0513E040E50A1EC03EEA) on dm01sw-ib3 because s_ntp_dm01sw-ib3.out not found skipping Infiniband Switch NTP configuration (checkid:- 9AD59DE0898D0513E040E50A1EC03EEA) on dm01sw-ib2 because s_ntp_dm01sw-ib2.out not found skipping Infiniband switch routing_engine configuration (checkid:- 9AD8F72CFE0AC95BE040E50A1EC050D0) on dm01sw-ib3 because s_opensm_dm01sw-ib3.out not found skipping Infiniband switch routing_engine configuration (checkid:- 9AD8F72CFE0AC95BE040E50A1EC050D0) on dm01sw-ib2 because s_opensm_dm01sw-ib2.out not found skipping Infiniband switch routing_engine configuration (checkid:- 9AD8F72CFE0AC95BE040E50A1EC050D0) on dm01sw-ib3 because s_opensm_dm01sw-ib3.out not found skipping Infiniband switch routing_engine configuration (checkid:- 9AD8F72CFE0AC95BE040E50A1EC050D0) on dm01sw-ib2 because s_opensm_dm01sw-ib2.out not found skipping Infiniband switch log_flags configuration (checkid:- 9ADA623709086DC5E040E50A1EC0168D) on dm01sw-ib3 because s_opensm_dm01sw-ib3.out not found skipping Infiniband switch log_flags configuration (checkid:- 9ADA623709086DC5E040E50A1EC0168D) on dm01sw-ib2 because s_opensm_dm01sw-ib2.out not found skipping Infiniband switch log_flags configuration (checkid:- 9ADA623709086DC5E040E50A1EC0168D) on dm01sw-ib3 because s_opensm_dm01sw-ib3.out not found skipping Infiniband switch log_flags configuration (checkid:- 9ADA623709086DC5E040E50A1EC0168D) on dm01sw-ib2 because s_opensm_dm01sw-ib2.out not found skipping Infiniband switch controlled_handover configuration (checkid:- 9ADAAD73FF532FE4E040E50A1EC0284E) on dm01sw-ib3 because s_opensm_dm01sw-ib3.out not found skipping Infiniband switch controlled_handover configuration (checkid:- 9ADAAD73FF532FE4E040E50A1EC0284E) on dm01sw-ib2 because s_opensm_dm01sw-ib2.out not found skipping Infiniband switch controlled_handover configuration (checkid:- 9ADAAD73FF532FE4E040E50A1EC0284E) on dm01sw-ib3 because s_opensm_dm01sw-ib3.out not found skipping Infiniband switch controlled_handover configuration (checkid:- 9ADAAD73FF532FE4E040E50A1EC0284E) on dm01sw-ib2 because s_opensm_dm01sw-ib2.out not found
CauseThe issue with the skipped checks on the IB switches was due to the old left-over files from the IB switches IB2 and IB3 /tmp location. SolutionA) As the root userid, remove the standard file /tmp/.exachk from the IB switches. References<BUG:18293524> - EXACHK EXECUTION REPORTS SOME SKIPPED CHECKS<BUG:18329202> - BAD MAGIC NUMBER IN SUPER-BLOCK WHILE TRYING TO OPEN Attachments This solution has no attachment |
||||||||||||||||||
|