Solution Type Problem Resolution Sure Solution 1627568.1 : SL500 - Robot Interlock Bent
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:Sun StorageTek SL500 Modular Library System - Version All Versions and laterInformation in this document applies to any platform. Flex has always done an inspection on these, and it is highly doubtful they ever ship one bent. We have seen DHL mix up defectives with FGI (Finished Goods Inventory) and ship broken robots. If the field receives one this way, they need to look at the box tape to see if it was factory sealed with water activated brown tape. If it has clear tape over the top, it has been opened before and a clear indicator it is not a new repair. SymptomsSL500 robot interlock bent. Seeing a lot of units with bent Interlock arms. CauseFlextronics Hypothesis: Interlock gets bent by FE or customers that don't open the door properly. SolutionRefer to the attached document for further details and pictures concerning the damaged front door interlock safety mechanism. Attachments This solution has no attachment |
||||||||||||||||
|