Asset ID: |
1-72-1625304.1 |
Update Date: | 2014-03-14 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
1625304.1
:
10GB/s Bonded NIC Is Running At 1GB/s
Related Categories |
- PLA-Support>Eng Systems>Exadata/ODA/SSC>Oracle Exadata>DB: Exadata_EST
|
In this Document
Created from <SR 3-8409338651>
Applies to:
Exadata X3-2 Hardware - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Symptoms
One of the main interface to the exadata machines is running at 1GB/s despite being on a 10GB/s network.
Cause
One of the network interfaces is flapping leading to very slow network performance
NICs eth4 and eth5 are bonded to bondeth0 and out of which eth5 is having issues, flapping up/down,
that is affecting the performance of the network on bondeth0.
Solution
In this instance, the SFP+ was replaced to cease the port flapping.
Attachments