Asset ID: |
1-72-1624015.1 |
Update Date: | 2017-09-26 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
1624015.1
:
T10000B - FSC5535, AUDIT_FSC_UNSEATED_CARTRIDGE_LEADER
Related Items |
- Sun StorageTek T10000B Tape Drive
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: Remote
|
In this Document
Created from <SR 3-8545125825>
Applies to:
Sun StorageTek T10000B Tape Drive - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.
Drives in report:
572004007617 Type: T10000B Rev: 1.50.203
Symptoms
3F08, 5535
FSC3F08, FSC5535
Cause
Found a perm error reported by the drive while trying to read a tape.
The drive was no able to engage the leader pin, so was not able to read the tape, its date or MIR/RFI parts. FSC reported 5535.
FSC Dictionary Description:
MODEL = T10000B
FSC = 3F08
(FSC Match Found in Rev. 1.50)
FSC: 3F08 RO_FSC_MIR_LAST_BLK_MISMATCH
MIM Code: NONE
FRU: STATUS ONLY CONF: 100%
Summary: |MIR-RFID STATUS |INFO | *** |
Field Text:
Information about the state of the MIR/RFID after a tape load.
FSC Dictionary Description:
MODEL = T10000B
FSC = 5535
(FSC Match Found in Rev. 1.50)
FSC: 5535 AUDIT_FSC_UNSEATED_CARTRIDGE_LEADER
MIM Code: NONE
FRU: HARDWARE CONF: 50%
FRU: MEDIA CONF: 50%
Summary: |TAPE |FILE REEL | *** |
Field Text:
The file reel moved unexpectedly during the time when the cartridge leader should be stationary (ears seated).
Solution
1. Unload the tape from the drive.
2. Eject it from the library.
3. Check if the leader is pulled inside the cartridge.
4. Check to see if other drives are able to load the cartridge.
The problem noted is address in microcode version 1.59.302. |
KB Link: |
1617034.1 |
Patch or Code Link: |
17968595 |
References
<NOTE:1546380.1> - T10000 A/B/C - FSC5535 - The File Reel Moved Unexpectedly During The Time When The Cartridge Leader Should be Stationary
Attachments