![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1622626.1 : Oracle ZFS Storage: ZS3-2 Initial Release Documentation has error with Disks and PCI slot locations.
In this Document
Applies to:Oracle ZFS Storage ZS3-2 - Version All Versions and later7000 Appliance OS (Fishworks) SymptomsDocumentation does not match actual product as far as disk slot and pci slot numbering.
CauseInitial documentation and online help had the disk drive and pci slots labeled incorrectly.
SolutionThe correct slot locations should be identified as below. top row: slot4(SSD) slot5(SSD) slot6 (filler) slot7 (filler)
bottom row: slot0(Boot Disk) slot1(Boot Disk) slot2(SSD) slot3(SSD)
top row: PCI Slot4 PCI Slot5 PCI Slot6
bottom row: PCI Slot1 PCI Slot2 PCI slot3
Documentation has been updated on docs.oracle.com. The correct documentation and slot designations can be found at
References<BUG:18177199> - BACKPORT 18116793 TO AK8-2013.1.1.5 ZS3-2 PCIE AND DRIVE SLOT NUMBERS INCORRECTAttachments This solution has no attachment |
||||||||||||||||||||||
|