Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1620530.1
Update Date:2017-09-26
Keywords:

Solution Type  Problem Resolution Sure

Solution  1620530.1 :   LTO6 - Drive Getting I/O Errors  


Related Items
  • IBM LTO6 Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: OEM Drive and Library
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-8228179091>

Applies to:

IBM LTO6 Tape Drive - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

Tape drive IO Fails within TSM

12/13/13   06:35:46      ANR8311E An I/O error occurred while accessing drive      
                         DRIVE32 (/dev/lin_tape/by-id/IBMtape500104F000A2D6B8) for
                         SETMODE operation, errno = 5, rc = 1. (SESSION: 17,      
                         PROCESS: 2)                                              
12/13/13   06:35:46      ANR8355E I/O error reading label for volume K00050 in    
                         drive DRIVE32 (/dev/lin_tape/by-id/IBMtape500104F000A2D6-
                         B8). (SESSION: 17, PROCESS: 2)                          

The lin_tape Driver Error log :
IBMtape53----00491  Fri Dec 13 06:35:47 2013
  Scsi Path   :  04 00 18 00
  CDB Command :  1A 00 10 00 FF 00
  Status Code :  00 0D 00 00
  Description : Unknown Host Error
---------------------------------------------------------------------
IBMtape53----00491  Fri Dec 13 06:38:24 2013
  Scsi Path   :  04 00 18 00
  CDB Command :  5F 00 00 00 00 00 00 00 18 00
  Status Code :  00 0D 00 00
  Description : Unknown Host Error

Messages
Dec 13 06:35:46 datsrv53 kernel: [51368.323254] lin_tape: IBMtape53----00491 tape_modesense_page failed: -5
Dec 13 06:38:24 datsrv53 kernel: [51525.995263] lin_tape: IBMtape53 tape_register_reservation_key failed, rc -5
Dec 13 06:38:24 datsrv53 kernel: [51525.995270] lin_tape: IBMtape53 failed release on close.


Cause

IBM LTO6s are Encryption capable and they will have Belisarius (Bel) Modules installed.
The purpose of this module in IBM LTOs is to multiplex the TTI & KMS signals to the IBM LTO 4, 5 & 6 drives and even though the Bel card is not actually multiplexing in our particular case, the code in this card  has been changed to increase the time out value to prevent bar code write failures, the reason for  intermittent I/O errors.

 

Solution

The recommendation is to install Bel code at  4.17.12.35,this is the latest.
It will be necessary to check out the timeout value when this code is loaded, it needs to be set to at least 60 Secs 

References

<NOTE:1546547.1> - IBM LTO - Process to Upgrade Belisarius Microcode On IBM LTO Drive
<NOTE:1496557.1> - OKM/KMS / IBM LTO - How To Set IBM LTO4/5 Drive Encryption Timeout Value on Belisarius Card, EMC RKM Solution