![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1619726.1 : New T4-1B Blades Are Not Communicating With SB6000 Chassis.
In this Document
Created from <SR 3-8341806441> Applies to:Sun Blade 6000 System - Version All Versions to All Versions [Release All Releases]SPARC SymptomsNot able to start cli on newly added Blades in SB6000 chassis. CauseThe issue occurs when newly added Blades with the ILOM version 3.1.x are added to a chassis running ILOM 3.0. The new Blades are 8.4.0.a, ILOM version 3.2.1.5, which has had some changes. Solution1. Upgrade of the original blades and chassis is recommended. or 2. Use 2 methods to power on and start the Blades References<NOTE:1009715.1> - Integrated Lights Out Manager (ILOM) CLI Quick Reference<NOTE:1494538.1> - Sun Blade 6000, 6048, or Netra 6000 chassis compatibility matrix for SPARC components <BUG:16093666> - UNABLE TO START CLI SHELL FROM CMM TO SP OF T5-1B BLADE <NOTE:1320879.1> - ILOM (Integrated Lights Out Manager/Hot-Tamale) page Attachments This solution has no attachment |
||||||||||||||||||
|