![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 1617047.1 : T10000C - Problems Addressed In 1.57.311 Code
In this Document
Applies to:StorageTek T10000C Tape Drive - Version Not Applicable to Not Applicable [Release N/A]Information in this document applies to any platform. Symptoms3660 37A0 Fixes a bug where T10KC drives were not previously reporting any servo diag wake-up errors. Note: Errors were being logged in the eventlog files but not displayed by VOP. RFE from a customer requesting T10KC supporting up to “512” active hosts (increase from previous maximum “256”). RFE from customer requesting DIVA (Front Porch) performance improvement when positioning to EOD using a space command when last position of the drive already was at EOD. Change eliminates a reconstitute of FSA sparse-wrap data which could take up to 34 seconds before this change. CauseProblems addressed in 1.57.311 code. SolutionInstall1.57.311 code to address above problems. Attachments This solution has no attachment |
||||||||||||||||
|