Solution Type  Problem Resolution Sure

Solution  1617047.1 :   T10000C - Problems Addressed In 1.57.311 Code  


Related Items
  • StorageTek T10000C Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Symptoms
Cause
Solution


Applies to:

StorageTek T10000C Tape Drive - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Symptoms

3660
FIX for SNO 3660 failure to reconstitute data from sparse wrap. Replaces special build RB57.308
Fixes a customer reported problem where Invalid MIR Tape Alert flag will cause VSM to not use the customer’s tapes. Replaces special build RA57308

37A0
Fix for SNO 37A0 (RO_FSC_NO_TARGET_REACHED_TYPE) during a read operation

Fixes a bug where T10KC drives were not previously reporting any servo diag wake-up errors. Note: Errors were being logged in the eventlog files but not displayed by VOP.

RFE from a customer requesting T10KC supporting up to “512” active hosts (increase from previous maximum “256”).

RFE from customer requesting DIVA (Front Porch) performance improvement when positioning to EOD using a space command when last position of the drive already was at EOD. Change eliminates a reconstitute of FSA sparse-wrap data which could take up to 34 seconds before this change.

Cause

 Problems addressed in 1.57.311 code.

Solution

Install1.57.311 code to address above problems.