Symptoms
Changes
Cause
Solution


Created from <SR 3-8054227926>

Applies to:

Sun StorageTek Crypto Key Management System - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

When trying to configure a SNMP manager in the OKM GUI, after adding the SNMP Manager ID, Description, Network address (trap receiver), checked 'Flags' and setting the SNMPv2 Protocol Version, then clicking 'save', the OKM GUI reports the following error:

'Verify that the SNMP Manager is reachable and is a valid SNMP Manager. Retry when reachable and, if using SNMPv3, specify a correct username and passphrase.'

Changes

 No Changes made

Cause

Customer is using HP openview which does not support snmp informs, it only supports traps
 

 

Solution

Use a SNMP monitoring software application that does support snmp informs.


 