![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1616312.1 : Oracle Key Manager (OKM) - Not Able To Register SNMP Manager to HP Openview
In this Document
Created from <SR 3-8054227926> Applies to:Sun StorageTek Crypto Key Management System - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. SymptomsWhen trying to configure a SNMP manager in the OKM GUI, after adding the SNMP Manager ID, Description, Network address (trap receiver), checked 'Flags' and setting the SNMPv2 Protocol Version, then clicking 'save', the OKM GUI reports the following error: 'Verify that the SNMP Manager is reachable and is a valid SNMP Manager. Retry when reachable and, if using SNMPv3, specify a correct username and passphrase.' ChangesNo Changes made CauseCustomer is using HP openview which does not support snmp informs, it only supports traps SolutionUse a SNMP monitoring software application that does support snmp informs.
Attachments This solution has no attachment |
||||||||||||||||||
|