![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1613159.1 : CRC Errors On ISL 8GB Port On Brocade300 - Vc_translation_link_init = 0 And Fillword = 0 = IDLE_IDLE
In this Document
Created from <SR 3-8199156111> Applies to:Brocade 300 Switch - Version All Versions and laterInformation in this document applies to any platform. SymptomsWe have a lot of CRC and Enc Out errors on ISL ports 14 and 15, 8GB long wave SFP used to connect 4 Brocade 300 switches FOS 6.4.3c
This shows the type of SFP 8GB Long Wave used: sfpshow -all :
============= Port 14: ============= Identifier: 3 SFP Connector: 7 LC Transceiver: 5401001200000000 200,400,800_MB/s SM lw Long_dist Encoding: 1 8B10B Baud Rate: 85 (units 100 megabaud) Length 9u: 10 (units km) Length 9u: 100 (units 100 meters) Length 50u: 0 (units 10 meters) Length 62.5u:0 (units 10 meters) Length Cu: 0 (units 1 meter) Vendor Name: BROCADE Vendor OUI: 00:05:1e Vendor PN: 57-1000027-01 Vendor Rev: A Wavelength: 1310 (units nm) Options: 003a Loss_of_Sig,Tx_Fault,Tx_Disable BR Max: 0 BR Min: 0 Serial No: UDN11317B100137 Date Code: 130429 DD Type: 0x68 Enh Options: 0xb0 Status/Ctrl: 0xa2 Alarm flags[0,1] = 0x5, 0x40 Warn Flags[0,1] = 0x5, 0x40 Alarm Warn low high low high Temperature: 40 Centigrade -15 100 -10 95 Current: 27.906 mAmps 5.000 80.000 10.000 70.000 Voltage: 3267.7 mVolts 2970.0 3600.0 3100.0 3470.0 RX Power: -3.4 dBm (456.7 uW) 25.1 uW 1412.5 uW 39.8 uW 891.2 uW TX Power: -2.6 dBm (550.7 uW) 89.1 uW 1412.5 uW 141.3 uW 891.3 uW
ChangesUsually the crc and enc out errors are caused by dirty cables, sfps or patch panels. Cause1) There is a defect that can explain CRC errors observed: The sfps in ports 14 and 15 begin with s/n UDN1xxxx.
There is a defect (DEFECT000414944) which these particular sfps caused CRC errors on 8G links. This has been corrected in FOS v 6.4.3e, v7.0.2a and v7.1.0. (Check the release notes)
2) In addition to that, there are some port parameter that are recommended by Brocade: ----------- 2GB and 4GB devices should be set to 0.
3) Another possible cause , that affect only to Brocade 300, is described by Brocade Technical Support Bulletin TSB-2012-011-O, it is a best practice, and it does not apply on our case as all SFPs are 8GB (short wave and long wave)
Solution1. Customer upgraded to latest v7.1.1a with applications up and running, on live systems, first will apply patch 149139-02 to go to v7.0.2c and then 150481-02: v7.1.1a
Wed Dec 18 17:55:09 2013 admin, 172.17.5.107, portdisable 15
Wed Dec 18 17:55:22 2013 admin, 172.17.5.107, portcfglongdistance 15 L0 Wed Dec 18 17:55:35 2013 admin, 172.17.5.107, portcfgfillword 15 0 Wed Dec 18 17:55:46 2013 admin, 172.17.5.107, portcfgcreditrecovery --disable 15 Wed Dec 18 17:55:54 2013 admin, 172.17.5.107, portenable 15 *** With this second action no more crc or enc out errors were observed. Wed Dec 18 18:27:40 2013 admin, 172.17.5.107, portdisable 14
Wed Dec 18 18:27:50 2013 admin, 172.17.5.107, portcfglongdistance 14 L0 Wed Dec 18 18:27:57 2013 admin, 172.17.5.107, portcfgfillword 14 0 Wed Dec 18 18:28:07 2013 admin, 172.17.5.107, portcfgcreditrecovery --disable 14 Wed Dec 18 18:28:29 2013 admin, 172.17.5.107, portenable 14
islshow :
1: 14-> 14 10:00:00:27:f8:98:e0:48 1 brocade1-A sp: 8.000G bw: 8.000G 2: 15-> 15 10:00:00:27:f8:98:e0:48 1 brocade1-A sp: 8.000G bw: 8.000G
portcfgshow : Ports of Slot 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 ----------------------+---+---+---+---+-----+---+---+---+-----+---+---+---+-----+---+---+--- Speed AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN Fill Word(On Active) 3 3 3 3 3 3 3 3 3 3 3 3 3 3 0 0 Fill Word(Current) 3 3 3 3 3 3 3 3 3 3 3 3 3 3 0 0 AL_PA Offset 13 .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. Trunk Port ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON Long Distance .. .. .. .. .. .. .. .. .. .. .. .. .. LE .. .. VC Link Init .. .. .. .. .. .. .. .. .. .. .. .. .. ON .. .. Locked L_Port - - - - - - - - - - - - - - - - Locked G_Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. Disabled E_Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. Locked E_Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ISL R_RDY Mode .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. RSCN Suppressed .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. Persistent Disable .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. LOS TOV enable .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. NPIV capability ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON NPIV PP Limit 126 126 126 126 126 126 126 126 126 126 126 126 126 126 126 126 QOS Port AE AE AE AE AE AE AE AE AE AE AE AE AE .. .. AE Mirror Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. Rate Limit .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. Credit Recovery ON ON ON ON ON ON ON ON ON ON ON ON ON ON .. .. Fport Buffers .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. Port Auto Disable .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. CSCTL mode .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. Fault Delay 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
porterrshow :
frames enc crc crc too too bad enc disc link loss loss frjt fbsy c3timeout pcs tx rx in err g_eof shrt long eof out c3 fail sync sig tx rx err 0: 607.1m 327.2m 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1: 3.7g 999.6m 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2: 1.2g 3.5g 0 0 0 0 0 0 105 1 0 0 0 0 0 0 0 0 3: 3.3g 2.4g 0 0 0 0 0 0 64 0 0 0 0 0 0 0 0 0 4: 1.5m 18 0 0 0 0 0 0 50 0 0 0 0 0 0 0 0 0 5: 321.7m 279.9m 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 6: 281.4m 321.7m 0 0 0 0 0 0 50 0 0 0 0 0 0 0 0 0 7: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 8: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 9: 2.4g 2.6g 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 10: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 12: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 14: 7.6m 2.3m 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 15: 11.3m 3.6m 0 0 0 0 0 0 0 23 0 0 0 0 0 0 0 0
References<NOTE:1003754.1> - Brocade: What logs are required to troubleshoot a Brocade switch?<NOTE:1519015.1> - How to Collect Brocade FC Switch logs <NOTE:1449866.2> - Information Center: Brocade 300 Switch <NOTE:1507746.1> - Oracle Fibre Channel (FC) SAN Switch Firmware Patch Matrix for Firmware Upgrade - Brocade - Cisco - McData - Qlogic Attachments This solution has no attachment |
||||||||||||||||||||
|