Solution Type  Problem Resolution Sure

Solution  1611666.1 :   CBUS_BT0 : Predictive Failure Asserted  


Related Items
  • Sun Netra T5440 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>CMT>SN-SPARC: T5xx0
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-8266897401>

Applies to:

Sun Netra T5440 Server - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Symptoms

System doesn't power on or keeps receiving errors at power on regarding CBUS_BTX failures

SC logs show:

### show /SP/logs/event/list

Fri Dec 20 14:54:25 2013 IPMI Log minor ID = 37 : 12/20/2013 : 14:54:25 : Slot/Connector : /MB/P0/CBUS_BT2 : Predictive Failure Deasserted
Fri Dec 20 14:50:45 2013 Chassis Log minor Degraded processor connection detected at /SYS/MB/CMP0/CBUS_BIT2
Fri Dec 20 14:50:25 2013 IPMI Log critical ID = 36 : 12/20/2013 : 14:50:25 : Slot/Connector : /MB/P0/CBUS_BT2 : Predictive Failure Asserted

### spos_logs/@var@log@plhwsvc.log

20131220143945:fmd DEBUG: etm: info: rcvd RESPONSE msg from xport
20131220144020:fmd DEBUG: etm: info: rcvd alert IPMI | critical: ID =   34 : 12/20/2013 : 14:40:19 : Slot/Connector
20131220144020: : /MB/P0/CBUS_BT2 : Predictive Failure Asserted
20131220144020:fmd DEBUG: etm: info: cnt 6
20131220144020:fmd DEBUG: etm: info: hdr xport write ok for alert IPMI | critical: ID =   34 : 12/20/2013 : 14:40:1
20131220144020:9 : Slot/Connector : /MB/P0/CBUS_BT2 : Predictive Failure Asserted

Cause

Failed Console Bus (CBUS) at specified CPU, in this example all in P0 (CMP0)
 

Solution

The console bus is used for diagnosis, configuration, and monitoring functions of the Platform.  Using the console bus is the only way to access many of the ASIC's status and control registers.  A failed CBUS requires that the systemboard to be replaced.  Please open a new Service Request to address these failures.