![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 1611382.1 : Abend E00 And C0D When Reading CA Encrypted Virtual Tapes via VSM6
In this Document
Created from <SR 3-8039050931> Applies to:Sun StorageTek Virtual Tape Control Software (VTCS) - Version 7.0 and laterSun StorageTek Enterprise Library Software (ELS) - Version 7.0 and later StorageTek Virtual Storage Manager System 6 (VSM6) - Version All Versions and later IBM z/OS on System z SymptomsRandom E00 or C0D abends when reading CA encrypted virtual tapes via the VSM6. Sometimes reading a VTV is successful, sometimes it is not. CauseThe source of this problem was discovered to be in the VSM6 microcode. SolutionUpgrade to VSM6 microcode level 6.0.6.09.000 or higher. Attachments This solution has no attachment |
||||||||||||||||
|