Solution Type  Problem Resolution Sure

Solution  1603068.1 :   Exadata ZFS Plugin exadata_bcu Script Reports Error On Create Project  


Related Items
  • Exadata X3-2 Quarter Rack
  •  
Related Categories
  • PLA-Support>Eng Systems>Exadata/ODA/SSC>Oracle Exadata>DB: Exadata_EST
  •  


Exadata Backup Configuration Utility (exadata_bcu ) script for ZFS Storage reports errors on creating project.

Created from <SR 3-8135282821>

Applies to:

Exadata X3-2 Quarter Rack - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

On : Exadata with Exadata ZFS Plugin

Exadata Backup Configuration Utility (exadata_bcu ) script for ZFS Storage reports errors on creating project.

ERROR
-----------------------

Creating project and shares on Pool1 ...
Error: failed to create project and shares on root@link1zfs.us.oracle.com
Error: create project failed - tstuat


STEPS
-----------------------
Customer executes the 'exadata_bcu' script from /opt/oracle.SupportTools/rman/exadata_bcu:

  tstuat1@dmcsdmdb01:/opt/oracle.SupportTools/rman/exadata_bcu%*>./exadata_bcu

Changes

 Attempting to run Exadata Backup Configuration Utility script, exadata_bcu to configure ZFS Storage appliance.

Cause

 netmask not passed when prompted to 'Enter the IPs of the Exadata for NFS rw access:'

Solution

Enter the IP Addresses  and netmask (in CIDR slash notation) when prompted to 'Enter the IPs of the Exadata for NFS rw access:'

 

For example:

Enter the IPs of the Exadata for NFS rw access:

Separate multiple entries by comma (,)

Example: 10.80.36.0/24,10.80.37.81/0 (netmask is required)

10.80.36.150/0,10.80.36.151/0,10.80.36.152/0,10.80.36.153/0

 

References

http://download.oracle.com/otn/other/storage-appliance/ebu/Exadata_BCU_UG_113.html