![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1603068.1 : Exadata ZFS Plugin exadata_bcu Script Reports Error On Create Project
Exadata Backup Configuration Utility (exadata_bcu ) script for ZFS Storage reports errors on creating project. Created from <SR 3-8135282821> Applies to:Exadata X3-2 Quarter Rack - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. SymptomsOn : Exadata with Exadata ZFS Plugin ChangesAttempting to run Exadata Backup Configuration Utility script, exadata_bcu to configure ZFS Storage appliance. Causenetmask not passed when prompted to 'Enter the IPs of the Exadata for NFS rw access:' SolutionEnter the IP Addresses and netmask (in CIDR slash notation) when prompted to 'Enter the IPs of the Exadata for NFS rw access:'
For example: Enter the IPs of the Exadata for NFS rw access: Separate multiple entries by comma (,) Example: 10.80.36.0/24,10.80.37.81/0 (netmask is required) 10.80.36.150/0,10.80.36.151/0,10.80.36.152/0,10.80.36.153/0
Referenceshttp://download.oracle.com/otn/other/storage-appliance/ebu/Exadata_BCU_UG_113.html<NOTE:1475967.1> - Known Issues - Exadata Backup Configuration Utility v1.1.0 Attachments This solution has no attachment |
||||||||||||
|