Asset ID: |
1-72-1602491.1 |
Update Date: | 2013-11-29 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
1602491.1
:
SNMPD Keeps Crashing On Brocade Fabric
Related Categories |
- PLA-Support>Sun Systems>DISK>Switch>SN-DK: Brocade Switch
|
In this Document
Created from <SR 3-8134350371>
Applies to:
Brocade 5000 Switch - Version All Versions and later
Information in this document applies to any platform.
Symptoms
unexpected termination of snmpd seen in the Brocade 500 Log Files [KSWD-1003] FFDC, WARNING, Brocade5000, kSWD: Detected unexpected termination of: snmpd:
Cause
the unexpected termination of snmpd is most likely caused due the known Defect ID: DEFECT000283566
Defect ID: DEFECT000283566
Technical Severity: High
Summary: Continuous SNMPd FFDC observed on switch during SNMP queries
Symptom: SNMPd FFDC will occur if a rare race condition is encountered
Feature: Field Escalation
Function: Management Embedded
Probability: Low
Found in Release: FOS6.1.1
Service Request ID: 421557
Solution
upgrade Brocade 5000 Switch to FOS v6.4.1b or higher.
Patch 144882-03 v6.4.1b
References
<NOTE:1507746.1> - Oracle Fibre Channel (FC) SAN Switch Firmware Patch Matrix for Firmware Upgrade - Brocade - Cisco - McData - Qlogic
Attachments