Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1601403.1
Update Date:2017-09-22
Keywords:

Solution Type  Problem Resolution Sure

Solution  1601403.1 :   SL8500 - 1310: "No Operational Hardware Path to Destination - final", sourceAddress=1,3,2,1,2 destinationAddress=1,3,47,2,3 volser=WY0489L4;  


Related Items
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-8120781797>

Applies to:

Sun StorageTek SL8500 Modular Library System - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Symptoms

 1310: "No Operational Hardware Path to Destination - final", sourceAddress=1,3,2,1,2 destinationAddress=1,3,47,2,3 volser=WY0489L4;

Cause

If the components are online, check the drive status (loaded with a different tape or empty) cartridge summary: Cartridge moved to the destination.

Solution

This indicates that this event was recovered after a retry and needs no action to be taken.

Login to the library SL console, observe the components status under Toos>System Details.

In this case: Robot in Rail 3, Drive 1.3.2.1.2 etc

References

<NOTE:1014752.1> - SL8500 - What Causes a Call Home Event on the SL8500?