![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1597870.1 : System Busy, Waiting 120 Seconds to Start Task Error Message
In this Document
Applies to:Acme Packet 4500 - Version S-Cx6.2.0 and laterInformation in this document applies to any platform. SymptomsThe error message "System busy, waiting 120 seconds to start task error message" shows up when trying to display the running-config. CauseWhen CLI (command line interface) "more" is enabled and one user is currently in the middle of displaying the running-config, any additional user who simultaneously executes the same show command will receive the following response when trying to display the configuration: SolutionOne option to wait the 120 seconds to get back to the telnet/SSH prompt, close the telnet session and open an entirely new session. There is no configurable method to change the 120 second timer, nor any way to break out of the waiting period. Note that this issue has been corrected in SCZ720m6p8 & SCZ730m2p1 and later patch releases. Please refer to the following MOS KM Document for details on how to find and download the latest patches:
References<BUG:24301565> - RUNNING CONFIG & BACKUP CONFIG: SYSTEM BUSY, WAITING 300 SECONDS TO START TASKAttachments This solution has no attachment |
||||||||||||||||||
|